Guidelines on the implementation of diode in vivo dosimetry programs for photon and electron external beam therapy.

R Alecu1, T Loomis, J Alecu, T Ochran.   

Abstract

Semiconductor diodes offer many advantages for clinical dosimetry: high sensitivity, real-time readout, simple instrumentation, robustness and air pressure independence. The feasibility and usefulness of in vivo dosimetry with diodes has been shown by numerous publications, but very few, if any, refer to the utilization of diodes in electron beam dosimetry. The purpose of this paper is to present our methods for implementing an effective IVD program for external beam therapy with photons and electrons and to evaluate a new type of diodes. Methods of deciding on reasonable action levels along with calibration procedures, established according to the type of measurements intended to be performed and the action limits, are discussed. Correction factors to account for nonreference clinical conditions for new types of diodes (designed for photon and electron beams) are presented and compared with those required by older models commercially available. The possibilities and limitations of each type of diode are presented, emphasizing the importance of using the appropriate diode for each task and energy range.

Mesh:

Year:  1999        PMID: 10100159     DOI: 10.1016/s0958-3947(98)00045-4

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  4 in total

1.  The semiconductor diode detector response as a function of field size and beam angle of high-energy photons.

Authors:  Tomasz Koper; Anna Kowalik; Sebastian Adamczyk
Journal:  Rep Pract Oncol Radiother       Date:  2017-04-21

2.  In vivo dosimetry using a single diode for megavoltage photon beam radiotherapy: implementation and response characterization.

Authors:  V C Colussi; A S Beddar; T J Kinsella; C H Sibata
Journal:  J Appl Clin Med Phys       Date:  2001       Impact factor: 2.102

3.  In-vivo dose measurements with MOSFET dosimeters during MV portal imaging.

Authors:  Sathish Kumar; Rabi Raja Singh; Henry Finlay Godson; Retna Ponmalar; Paul Ravindran; Sunil Dutt Sharma; Subhashini John
Journal:  Rep Pract Oncol Radiother       Date:  2021-02-25

4.  Characterization of an in vivo diode dosimetry system for clinical use.

Authors:  Kai Huang; William S Bice; Oscar Hidalgo-Salvatierra
Journal:  J Appl Clin Med Phys       Date:  2003       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.