Time-related alterations in shape, position, and structure of self-expanding, modular aortic stent-grafts: a 4-year single-center follow-up.

T Umscheid1, W J Stelter.   

Abstract

PURPOSE: To report the nature and ramifications of structural and positional changes over time in tube and modular bifurcated aortic stent-grafts.
METHODS: Two hundred ninety-one patients received endovascular aortic grafts (primarily Stentor/Vanguard) between August 1994 and August 1998. Follow-up surveillance (clinical and laboratory examination, biplanar noncontrast radiography, and contrast-enhanced computed tomography) has been maintained on all patients for 4 years. Changes in the configuration and position of endografts have been noted and their sequelae charted.
RESULTS: Three types of endograft shape changes have been documented: mild -- slight distortions visible on plain radiographs (n = 90, 31.0%), significant -- angulations reaching 60 degrees to 90 degrees (n = 65, 22.3%), and severe -- angulations > or = 90 degrees (n = 10, 3.4%). Changes in position never gave rise to late migration at the proximal attachment site, whereas at the distal ends, the endograft easily retracted from the iliac arteries (n = 8). Structural alterations (rupture of the stent frame, sutures, or fabric, and total graft disintegration) were more common in the original Stentor model. Shape, position, and structural alterations were mutually dependent and led to secondary endoleaks (n = 26) and graft limb thrombosis (n = 37). Late surgical conversion was necessary in 3 (1.0%) patients.
CONCLUSIONS: Tortuosity of the native vessels is a source of complication in long-term follow-up just as it is during implantation. Given the late appearance of complications in this patient cohort, it would seem that the durability of an endograft cannot be evaluated with < 3 years of follow-up.

Entities:  

Mesh:

Year:  1999        PMID: 10088887     DOI: 10.1583/1074-6218(1999)006<0017:TRAISP>2.0.CO;2

Source DB:  PubMed          Journal:  J Endovasc Surg        ISSN: 1074-6218


  9 in total

1.  Mathematical Model analysis of Wallstent and Aneurx: dynamic responses of bare-metal endoprosthesis compared with those of stent-graft.

Authors:  Suncica Canic; K Ravi-Chandar; Zvonimir Krajcer; Dragan Mirkovic; Serguei Lapin
Journal:  Tex Heart Inst J       Date:  2005

2.  Effect of curvature on displacement forces acting on aortic endografts: a 3-dimensional computational analysis.

Authors:  C Alberto Figueroa; Charles A Taylor; Victoria Yeh; Allen J Chiou; Christopher K Zarins
Journal:  J Endovasc Ther       Date:  2009-06       Impact factor: 3.487

3.  Renewed endovascular repair for recurrent acute abdominal aortic aneurysm.

Authors:  Umberto M Bracale; Clark J Zeebregts; Ben R Saleem; Ted R Prins; Eric L G Verhoeven
Journal:  Emerg Radiol       Date:  2008-05-15

4.  Endovascular repair of abdominal aortic aneurysms.

Authors:  W C Sternbergh; M Yoselevitz; S R Money
Journal:  Ochsner J       Date:  1999-10

5.  Factors affecting the regression of surgically replaced abdominal aortic aneurysms.

Authors:  Masahiro Matsushita; Teruo Ikezawa
Journal:  Surg Today       Date:  2006       Impact factor: 2.549

Review 6.  Acute Traumatic Thoracic Aortic Injury: Considerations and Reflections on the Endovascular Aneurysm Repair.

Authors:  Luca Di Marco; Davide Pacini; Roberto Di Bartolomeo
Journal:  Aorta (Stamford)       Date:  2013-07-01

7.  Endovascular stent graft repair of abdominal and thoracic aortic aneurysms: a ten-year experience with 817 patients.

Authors:  Michael L Marin; Larry H Hollier; Sharif H Ellozy; David Spielvogel; Harold Mitty; Randall Griepp; Robert A Lookstein; Alfio Carroccio; Nicholas J Morrissey; Victoria J Teodorescu; Tikva S Jacobs; Michael E Minor; Claudie M Sheahan; Kristina Chae; Juliana Oak; Andrew Cha
Journal:  Ann Surg       Date:  2003-10       Impact factor: 12.969

8.  Mechanical trauma as a cause of late complications: after AneuRx Stent Graft repair of abdominal aortic aneurysms.

Authors:  Zvonimir Krajcar; Kamal Gupta; Kathy G Dougherty
Journal:  Tex Heart Inst J       Date:  2003

9.  A Case of Endovascular Treatment of Severe Graft Limb Kinking after Endovascular Abdominal Aortic Aneurysm Repair.

Authors:  Jong-Beom Shin; Mi-Hwa Park; Sang-Ho Jeong; Sung Woo Kwon; Sung-Hee Shin; Seong-Ill Woo; Sang-Don Park
Journal:  Vasc Specialist Int       Date:  2016-03-31
  9 in total