Literature DB >> 1008730

[Evaluation of loosening of different total hip models and neck lengths (author's transl)].

D Tönnis, H Asai.   

Abstract

The percentage of aseptic loosening of different types of total hip prostheses in 771 cases has been evaluated. The time of follow-up ranged between 1/2 and 6 years. In prostheses of the Charnley-Müller type of loosening was 7.8% in the Charnley-Müller-Weller type with a 2-year shorter follow-up it was 2.4%. No loosening was found during the last 2 1/2 years when the prosthesis of Beck was used, which has an increased femoral shaft-neck angle and a longer stem. When a longer neck was used, the loosening averaged 5.6%. In cases of normal neck-length it was 3.6%. From the biomechanical standpoint it seems preferable to use prostheses with an increased shaft-neck angle. Comparing the rates of loosening as reported in the literature it appears that prostheses where the femur is displaced medially (by a small femoral head or increased shaft-neck angle) show a very low rate of loosening. Models with metal sockets (McKee-Farrar and Weber-Huggler) seem to have a higher rate of loosening than models with polyethylene sockets.

Entities:  

Mesh:

Year:  1976        PMID: 1008730     DOI: 10.1007/bf00418908

Source DB:  PubMed          Journal:  Arch Orthop Unfallchir        ISSN: 0003-9330


  21 in total

1.  [The influence of surgically introduced muscle tension on the function of total hip prostheses (author's transl)].

Authors:  W Kuhfuss; M Schildhauer; D Tönnis
Journal:  Z Orthop Ihre Grenzgeb       Date:  1975-06

2.  [Bone stress and reconstruction of the bone at the alloarthroplasty of the upper end of the femur with cement bonding (author's transl)].

Authors:  K Diehl
Journal:  Arch Orthop Unfallchir       Date:  1975-09-04

3.  [Therapeutic approaches to implant loosening in total hip arthroplasty (author's transl)].

Authors:  A N Witt; M H Hackenbroch
Journal:  Z Orthop Ihre Grenzgeb       Date:  1976-06

4.  Results of the total hip prosthesis design "St. George".

Authors:  H W Buchholz; G Noack
Journal:  Clin Orthop Relat Res       Date:  1973-09       Impact factor: 4.176

5.  [Proceedings: The present state of total hip joint prosthesis].

Authors:  M E Müller
Journal:  Z Orthop Ihre Grenzgeb       Date:  1974-08

6.  Experience with low-friction arthroplasty. A statistical review of early results and complications.

Authors:  N S Eftekhar; F E Stinchfield
Journal:  Clin Orthop Relat Res       Date:  1973-09       Impact factor: 4.176

7.  The nine and ten year results of the low-friction arthroplasty of the hip.

Authors:  J Charnley; Z Cupic
Journal:  Clin Orthop Relat Res       Date:  1973-09       Impact factor: 4.176

8.  700 total hip replacements. Experience with 6 types.

Authors:  I S Leinbach; F A Barlow
Journal:  Clin Orthop Relat Res       Date:  1973-09       Impact factor: 4.176

9.  Experience with the McKee-Farrar total hip replacement. A report of 143 operations.

Authors:  P Salenius; L E Laurent
Journal:  Acta Orthop Scand       Date:  1973

10.  [Further experiences with total hip arthroplasty. Clinical and roentgenographic results after 3--6 years following implantation (author's transl)].

Authors:  M H Hackenbroch; H Bruns; R Holbe; H Lechleuthner
Journal:  Arch Orthop Unfallchir       Date:  1976-03-26
View more
  4 in total

1.  Failures of total hip arthroplasty and probable incidence of revision surgery in the future. Calculations according to a mathematical model based on a ten years' experience in total hip arthroplasty.

Authors:  E Morscher; A Schmassmann
Journal:  Arch Orthop Trauma Surg       Date:  1983

2.  An analysis of 119 loosenings in total hip endoprostheses.

Authors:  P Bösch; H Kristen; K Zweymüller
Journal:  Arch Orthop Trauma Surg       Date:  1980

3.  Technological test-methods for hip prostheses.

Authors:  M Ungethüm
Journal:  Arch Orthop Trauma Surg       Date:  1980

Review 4.  Results of alloarthroplasty of the hip joint.

Authors:  W Oberthaler; R Bauer; K Sattler
Journal:  Arch Orthop Trauma Surg       Date:  1980
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.