Literature DB >> 10077035

CBF and CBV measurements by USPIO bolus tracking: reproducibility and comparison with Gd-based values.

C Z Simonsen1, L Ostergaard, P Vestergaard-Poulsen, L Røhl, A Bjørnerud, C Gyldensted.   

Abstract

The authors measured cerebral blood flow (CBF) and cerebral blood volume (CBV) by bolus tracking of a novel ultrasmall superparamagnetic iron oxide (USPIO) contrast agent (NC100150) and compared absolute and relative perfusion measurements with those obtained by a standard gadolinium-based contrast agent. They found a linear correlation between the two methods. A dose of 0.4 mg Fe/kg body weight was found to produce a signal drop similar to that of a standard 0.2 mmol/kg gadodiamide injection using spin-echo echoplanar imaging (SE-EPI) at 1.0 T. The measurements showed a high degree of reproducibility of repeated absolute as well as relative CBF and CBV values, lending further hope to the possibility of using magnetic resonance bolus tracking for routine CBF and CBV measurements. Finally, the authors present their initial experience with high-resolution, non-EPI CBV maps obtained from steady-state levels of an intravascular superparamagnetic contrast agent.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10077035     DOI: 10.1002/(sici)1522-2586(199902)9:2<342::aid-jmri29>3.0.co;2-b

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  20 in total

1.  Extraction of the first bolus passage in dynamic susceptibility contrast perfusion measurements.

Authors:  Peter Gall; Irina Mader; Valerij G Kiselev
Journal:  MAGMA       Date:  2009-04-21       Impact factor: 2.310

Review 2.  Enabling individualized therapy through nanotechnology.

Authors:  Jason H Sakamoto; Anne L van de Ven; Biana Godin; Elvin Blanco; Rita E Serda; Alessandro Grattoni; Arturas Ziemys; Ali Bouamrani; Tony Hu; Shivakumar I Ranganathan; Enrica De Rosa; Jonathan O Martinez; Christine A Smid; Rachel M Buchanan; Sei-Young Lee; Srimeenakshi Srinivasan; Matthew Landry; Anne Meyn; Ennio Tasciotti; Xuewu Liu; Paolo Decuzzi; Mauro Ferrari
Journal:  Pharmacol Res       Date:  2010-01-05       Impact factor: 7.658

Review 3.  Macromolecules, dendrimers, and nanomaterials in magnetic resonance imaging: the interplay between size, function, and pharmacokinetics.

Authors:  Aaron Joseph L Villaraza; Ambika Bumb; Martin W Brechbiel
Journal:  Chem Rev       Date:  2010-05-12       Impact factor: 60.622

Review 4.  Absolute quantification of perfusion using dynamic susceptibility contrast MRI: pitfalls and possibilities.

Authors:  Linda Knutsson; Freddy Ståhlberg; Ronnie Wirestam
Journal:  MAGMA       Date:  2009-12-04       Impact factor: 2.310

5.  Evaluation of zinc-doped magnetite nanoparticle toxicity in the liver and kidney of mice after sub-chronic intragastric administration.

Authors:  Shanshan Zhu; Xiaolong Xu; Rui Rong; Bing Li; Xue Wang
Journal:  Toxicol Res (Camb)       Date:  2015-11-18       Impact factor: 3.524

Review 6.  Magnetic nanoparticles: an emerging technology for malignant brain tumor imaging and therapy.

Authors:  Mamta Wankhede; Alexandros Bouras; Milota Kaluzova; Costas G Hadjipanayis
Journal:  Expert Rev Clin Pharmacol       Date:  2012-03       Impact factor: 5.045

7.  Increased hippocampal blood volume and normal blood flow in schizophrenia.

Authors:  Pratik Talati; Swati Rane; Jack Skinner; John Gore; Stephan Heckers
Journal:  Psychiatry Res       Date:  2015-04-03       Impact factor: 3.222

8.  Pre-clinical results with Clariscan (NC100150 Injection); experience from different disease models.

Authors:  A Bjørnerud; L O Johansson; H K Ahlström
Journal:  MAGMA       Date:  2001-05       Impact factor: 2.310

9.  Perfusional deficit and the dynamics of cerebral edemas in experimental traumatic brain injury using perfusion and diffusion-weighted magnetic resonance imaging.

Authors:  Anne Pasco; Laurent Lemaire; Florence Franconi; Yann Lefur; Fanny Noury; Jean-Paul Saint-André; Jean-Pierre Benoit; Patrick J Cozzone; Jean-Jacques Le Jeune
Journal:  J Neurotrauma       Date:  2007-08       Impact factor: 5.269

10.  Assessment of a combined spin- and gradient-echo (SAGE) DSC-MRI method for preclinical neuroimaging.

Authors:  Ashley M Stokes; Jack T Skinner; C Chad Quarles
Journal:  Magn Reson Imaging       Date:  2014-08-28       Impact factor: 2.546

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.