New low-contrast resolution phantoms for computed tomography.

C Suess1, W A Kalender, J M Coman.   

Abstract

Computed tomography (CT) has been established as a major imaging modality in diagnostic radiology. Accordingly, acceptance testing and quality control of CT scanners is of great importance. While most procedures and phantoms for testing are widely accepted, there is still discussion and uncertainty about low-contrast (LC) sensitivity. In our opinion this unsatisfactory situation is caused at least in part by the lack of suitable phantoms for LC resolution measurements. We investigated the commonly used phantoms for LC detectability, the Catphan, and for LC resolution, the ATS phantom. While the Catphan showed stable object contrasts, the ATS phantom's measured contrast exhibited a strong dependence on temperature and x-ray quality. Based on newly developed polyurethane resin materials, we designed and tested a LC resolution phantom with several different contrast steps. The object contrasts showed no dependence on temperature and beam quality. The new LC resolution phantom proved to be very suitable for measuring a scanner's low-contrast sensitivity in the image plane, one of the most important image quality parameters. To assess LC resolution in three dimensions we designed an additional phantom with rows of spherical objects. A first prototype was evaluated in a multicenter study. The setup proved to be very helpful to quantify the in-plane and axial LC sensitivity of spiral CT scan modes.

Entities:  

Mesh:

Year:  1999        PMID: 10076988     DOI: 10.1118/1.598516

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  A computer-simulated liver phantom (virtual liver phantom) for multidetector computed tomography evaluation.

Authors:  Yoshinori Funama; Kazuo Awai; Osamu Miyazaki; Yoshiharu Nakayama; Da Liu; Taiga Goto; Yasuyuki Yamashita; Shinichi Hori
Journal:  Eur Radiol       Date:  2005-10-20       Impact factor: 5.315

2.  Spatial resolution measurement for iterative reconstruction by use of image-averaging techniques in computed tomography.

Authors:  Atsushi Urikura; Katsuhiro Ichikawa; Takanori Hara; Eiji Nishimaru; Yoshihiro Nakaya
Journal:  Radiol Phys Technol       Date:  2014-06-01

3.  Development and applicability of a quality control phantom for dental cone-beam CT.

Authors:  Ruben Pauwels; Harry Stamatakis; Giorgos Manousaridis; Adrian Walker; Koen Michielsen; Hilde Bosmans; Ria Bogaerts; Reinhilde Jacobs; Keith Horner; Kostas Tsiklakis
Journal:  J Appl Clin Med Phys       Date:  2011-11-15       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.