Literature DB >> 10076140

Ultrasonographic measurement of liver length in the small-for-gestational-age fetus.

A B Roberts1, J M Mitchell, L M McCowan, S Barker.   

Abstract

OBJECTIVE: Our purpose was to measure fetal liver size in small-for-gestational-age fetuses diagnosed by ultrasonography and to determine whether the small abdominal circumference used to diagnose small for gestational age is the result of a small liver. STUDY
DESIGN: Ninety-eight pregnant women who were diagnosed as having a fetus that was small for gestational age were included. All had a fetal ultrasonographic measurement of abdominal circumference <10th percentile for gestational age. Measurements were made of the length of the right lobe of the fetal liver within 2 weeks of delivery. The liver length measurements were compared with data collected from a normal population that had been previously published by the authors. The group of fetuses with liver length measurements <10th percentile for gestational age were compared with those with liver length measurements within normal limits.
RESULTS: Liver length measurements were >10th percentile in 80 fetuses (82%). Eighteen fetuses (18%) had small liver lengths, and this group had significantly smaller antenatal ultrasonographic measurements of head, abdomen, and femur. They were smaller at birth with smaller placentas and they had a higher perinatal mortality rate.
CONCLUSION: The small abdominal circumference measurement that is the mainstay of ultrasonographic diagnosis of small for gestational age is thought to be a reflection of fetal liver size. This study questions that assumption. The majority of small-for-gestational-age fetuses in this small study did not have small liver lengths. The small abdominal circumference measurement may reflect a reduction in size of other intra-abdominal organs, reduced amounts of fat, or possibly an elevated diaphragm because of poor lung growth.

Entities:  

Mesh:

Year:  1999        PMID: 10076140     DOI: 10.1016/s0002-9378(99)70266-8

Source DB:  PubMed          Journal:  Am J Obstet Gynecol        ISSN: 0002-9378            Impact factor:   8.661


  5 in total

1.  Fetal Liver Volume Assessment Using Magnetic Resonance Imaging in Fetuses With Cytomegalovirus Infection.

Authors:  Ameth Hawkins-Villarreal; Ana L Moreno-Espinosa; Raigam J Martinez-Portilla; Karen Castillo; Nadine Hahner; Ayako Nakaki; Lucas Trigo; Olivier Picone; Nathalie Siauve; Francesc Figueras; Alfons Nadal; Elisenda Eixarch; Anna Goncé
Journal:  Front Med (Lausanne)       Date:  2022-05-16

2.  Three-dimensional growth dynamics of the liver in the human fetus.

Authors:  Michał Szpinda; Monika Paruszewska-Achtel; Alina Woźniak; Mateusz Badura; Celestyna Mila-Kierzenkowska; Marcin Wiśniewski
Journal:  Surg Radiol Anat       Date:  2015-02-03       Impact factor: 1.246

3.  Can a Difference in Gestational Age According to Biparietal Diameter and Abdominal Circumference Predict Intrapartum Placental Abruption?

Authors:  Jee-Youn Hong; Jin-Ha Kim; Seo-Yeon Kim; Ji-Hee Sung; Suk-Joo Choi; Soo-Young Oh; Cheong-Rae Roh
Journal:  J Clin Med       Date:  2021-05-29       Impact factor: 4.241

4.  Volumetric Growth of the Liver in the Human Fetus: An Anatomical, Hydrostatic, and Statistical Study.

Authors:  Michał Szpinda; Monika Paruszewska-Achtel; Alina Woźniak; Celestyna Mila-Kierzenkowska; Gabriela Elminowska-Wenda; Małgorzata Dombek; Anna Szpinda; Mateusz Badura
Journal:  Biomed Res Int       Date:  2015-08-27       Impact factor: 3.411

5.  Hepato - Cephalic Index as a Predictor of Intrauterine Growth Restriction.

Authors:  Ramadan Dacaj; Sebija Izetbegovic; Goran Stojkanovic; Curr Gjocaj
Journal:  Acta Inform Med       Date:  2016-02-02
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.