Literature DB >> 10074550

Rapid identification of Staphylococcus aureus by using fluorescent staphylocoagulase assays.

M G Holliday1, M Ford, J D Perry, F K Gould.   

Abstract

Two rapid (1-h) assays for the detection of Staphylococcus aureus staphylocoagulase were developed by using the fluorogenic thrombin substrates N-t-boc-Val-Pro-Arg-7-amido-4-methylcoumarin (VPA) and N-t-boc-beta-benzyl-Asp-Pro-Arg-7-amido-4-methylocoumarin (BB). The assays were compared to the tube coagulase test and latex agglutination (LA) (Sanofi Diagnostics Pasteur, Guildford, Surrey, United Kingdom) by using 406 clinical isolates of staphylococci, and they produced positive and negative predictive values of 99.2 and 99. 1% for LA, 98.9 and 92.7% for VPA, and 98.9 and 99.1% for BB. Fluorescent assays used colonies from solid media, thereby eliminating the need for broth cultures, and were performed in microtiter trays, thus making them suitable for large-scale screening.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10074550      PMCID: PMC88673     

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  14 in total

1.  Interpretation of the tube coagulase test for identification of Staphylococcus aureus.

Authors:  W H Sperber; S R Tatini
Journal:  Appl Microbiol       Date:  1975-04

2.  Comparison of the staphylocoagulase activities of Staphylococcus aureus and Staphylococcus intermedius on Chromozym-TH.

Authors:  J Raus; D N Love
Journal:  J Clin Microbiol       Date:  1990-02       Impact factor: 5.948

3.  Fibrinogen-binding protein/clumping factor from Staphylococcus aureus.

Authors:  M K Bodén; J I Flock
Journal:  Infect Immun       Date:  1989-08       Impact factor: 3.441

4.  Identification of Staphylococcus aureus by simultaneous use of tube coagulase and thermonuclease tests.

Authors:  A L Barry; R V Lachica; F W Atchison
Journal:  Appl Microbiol       Date:  1973-03

5.  Pseudocoagulase activity of staphylococci.

Authors:  Z Wegrzynowicz; P B Heczko; J Jeljaszewicz; M Neugebauer; G Pulverer
Journal:  J Clin Microbiol       Date:  1979-01       Impact factor: 5.948

6.  Comparative performances of six agglutination kits assessed by using typical and atypical strains of Staphylococcus aureus.

Authors:  P Personne; M Bes; G Lina; F Vandenesch; Y Brun; J Etienne
Journal:  J Clin Microbiol       Date:  1997-05       Impact factor: 5.948

7.  Evaluation of three test procedures for identification of Staphylococcus aureus from clinical sources.

Authors:  J Y Zarzour; E A Belle
Journal:  J Clin Microbiol       Date:  1978-02       Impact factor: 5.948

Review 8.  Methicillin-resistant Staphylococcus aureus: a consensus review of the microbiology, pathogenesis, and epidemiology with implications for prevention and management.

Authors:  M E Mulligan; K A Murray-Leisure; B S Ribner; H C Standiford; J F John; J A Korvick; C A Kauffman; V L Yu
Journal:  Am J Med       Date:  1993-03       Impact factor: 4.965

9.  Enzymatic properties of staphylothrombin, an active molecular complex formed between staphylocoagulase and human prothrombin.

Authors:  S Kawabata; T Morita; S Iwanaga; H Igarashi
Journal:  J Biochem       Date:  1985-12       Impact factor: 3.387

10.  Rapid and direct staphylocoagulase assay that uses a chromogenic substrate for identification of Staphylococcus aureus.

Authors:  W Engels; M A Kamps; C P van Boven
Journal:  J Clin Microbiol       Date:  1981-11       Impact factor: 5.948

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.