Electron contamination and build-up doses in conformal radiotherapy fields.

A R Hounsell1, J M Wilkinson.   

Abstract

The dose in the build-up region depends upon the primary photon beam, backscattered radiation from the patient and contamination radiation from outside the patient. In this paper, a model based on measured data is proposed which allows the build-up dose for arbitrarily shaped treatment fields to be determined. The dose in the build-up region is assumed to comprise a primary photon component and a contamination component that is a function of the field size and shape. This contamination component, for modelling purposes, is subdivided into contributions that correspond to elements of 1 cm by 1 cm cross-sectional area at the plane of the isocentre. The magnitude of these components has been obtained by fitting measured data to an exponential function. The exponent was found to vary linearly with depth for energies between 4 MV and 20 MV. The coefficient decreased linearly with depth at 4, 6 and 8 MV, but exhibited a broad build-up region at 20 MV. The primary component, in the build-up region, could be approximated by a 100 - (100 - PSD) e(-mu d) function, where PSD is the primary surface dose. The values obtained during the fitting procedure were used to calculate dose in the build-up region for arbitrarily shaped fields. Good agreement was found in each case.

Entities:  

Mesh:

Year:  1999        PMID: 10071874     DOI: 10.1088/0031-9155/44/1/005

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Verification of dose calculations with a clinical treatment planning system based on a point kernel dose engine.

Authors:  Lars Weber; Per Nilsson
Journal:  J Appl Clin Med Phys       Date:  2002       Impact factor: 2.102

2.  Verification of IMRT dose calculations using AAA and PBC algorithms in dose buildup regions.

Authors:  Arun S Oinam; Lakhwant Singh
Journal:  J Appl Clin Med Phys       Date:  2010-08-26       Impact factor: 2.102

3.  Surface buildup dose dependence on photon field delivery technique for IMRT.

Authors:  Shigeru Yokoyama; Peter L Roberson; Dale W Litzenberg; Jean M Moran; Benedick A Fraass
Journal:  J Appl Clin Med Phys       Date:  2004-04-01       Impact factor: 2.102

4.  Assessment of the accuracy of dose calculation in the build-up region of the tangential field of the breast for a radiotherapy treatment planning system.

Authors:  Bagher Farhood; Mohammad Taghi Bahreyni Toossi; Shokouhozaman Soleymanifard; Tohid Mortezazadeh
Journal:  Contemp Oncol (Pozn)       Date:  2017-09-29

5.  Surface and buildup dose characteristics for 6, 10, and 18 MV photons from an Elekta Precise linear accelerator.

Authors:  Eric E Klein; Jacqueline Esthappan; Zuofeng Li
Journal:  J Appl Clin Med Phys       Date:  2003       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.