OBJECTIVE: The incidence of retethering caused by postoperative adhesions at the repair site after initial tethered spinal cord surgery is not uncommon. To assess the effectiveness of a Gore-Tex membrane in preventing these adhesions, only clinical radiological and experimental animal evaluation has been reported. In this report, we describe two cases in which Gore-Tex membrane was implanted at the initial untethering surgery and in which we were able to confirm the real effectiveness of the Gore-Tex membrane during a second operation. METHODS: In the first patient, Gore-Tex membrane was used for dural repair in the untethering surgery of the split spinal cord malformation. Because of the suspicion of a thickened filum terminale, repeated surgery was indicated 10 months after the initial procedure. In the second patient, Gore-Tex membrane was implanted during the initial untethering surgery for a lipomyeloschisis and a dermal sinus. Because of a persistent fistula of the dermal sinus, a second operation was necessary 1 year after the first operation. RESULTS: During the repeated surgery, a thorough inspection of the implanted Gore-Tex membrane revealed no adhesions between the Gore-Tex membrane and the intradural content in both cases. CONCLUSION: We support the use of Gore-Tex membrane in the prevention of postoperative dural adhesions in the repair of spinal dysraphism.
OBJECTIVE: The incidence of retethering caused by postoperative adhesions at the repair site after initial tethered spinal cord surgery is not uncommon. To assess the effectiveness of a Gore-Tex membrane in preventing these adhesions, only clinical radiological and experimental animal evaluation has been reported. In this report, we describe two cases in which Gore-Tex membrane was implanted at the initial untethering surgery and in which we were able to confirm the real effectiveness of the Gore-Tex membrane during a second operation. METHODS: In the first patient, Gore-Tex membrane was used for dural repair in the untethering surgery of the split spinal cord malformation. Because of the suspicion of a thickened filum terminale, repeated surgery was indicated 10 months after the initial procedure. In the second patient, Gore-Tex membrane was implanted during the initial untethering surgery for a lipomyeloschisis and a dermal sinus. Because of a persistent fistula of the dermal sinus, a second operation was necessary 1 year after the first operation. RESULTS: During the repeated surgery, a thorough inspection of the implanted Gore-Tex membrane revealed no adhesions between the Gore-Tex membrane and the intradural content in both cases. CONCLUSION: We support the use of Gore-Tex membrane in the prevention of postoperative dural adhesions in the repair of spinal dysraphism.
Authors: Roger Samuels; Matthew J McGirt; Frank J Attenello; Giannina L Garcés Ambrossi; Neil Singh; Can Solakoglu; Jon D Weingart; Benjamin S Carson; George I Jallo Journal: Childs Nerv Syst Date: 2009-05-06 Impact factor: 1.475
Authors: Ceren Kizmazoglu; Hasan Emre Aydin; Ismail Kaya; Murat Atar; Bugra Husemoglu; Orhan Kalemci; Gulden Sozer; Hasan Havitcioglu Journal: J Korean Neurosurg Soc Date: 2019-10-30