Literature DB >> 10065891

The combination of magnetic resonance angiography and computational fluid dynamics: a critical review.

Q Long1, X Y Xu, M W Collins, T M Griffith, M Bourne.   

Abstract

Computational Fluid Dynamics (CFD) has proven to be a valuable technique in the study of blood flow in arteries because of its capability of obtaining quantitatively velocities and wall shear stress. However, the "bottleneck" problem limiting the application of CFD is the difficulty of constructing anatomically realistic arterial geometries. In this survey, an overview is presented of the progress over the last decade in the development of magnetic resonance angiography (MRA) techniques, medical image processing and CFD, as well as the combination of these techniques in hemodynamics research. It is demonstrated that with modern angiographic techniques such as MRA, noninvasive measurement of human angiograms becomes possible and practical. Together with digital medical image processing and analysis techniques, computational models can be constructed for the "real" human arteries without making any geometric assumptions. When allied with state-of-the-art CFD codes, velocity and wall shear stress distributions, as well as particle trajectories, can be determined in the arteries.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 10065891     DOI: 10.1615/critrevbiomedeng.v26.i4.10

Source DB:  PubMed          Journal:  Crit Rev Biomed Eng        ISSN: 0278-940X


  5 in total

Review 1.  An image-based modeling framework for patient-specific computational hemodynamics.

Authors:  Luca Antiga; Marina Piccinelli; Lorenzo Botti; Bogdan Ene-Iordache; Andrea Remuzzi; David A Steinman
Journal:  Med Biol Eng Comput       Date:  2008-11-11       Impact factor: 2.602

2.  Comparing velocity and fluid shear stress in a stenotic phantom with steady flow: phase-contrast MRI, particle image velocimetry and computational fluid dynamics.

Authors:  Iman Khodarahmi
Journal:  MAGMA       Date:  2014-12-12       Impact factor: 2.310

3.  Wall shear stress measurement using phase contrast magnetic resonance imaging with phase contrast magnetic resonance angiography in arteriovenous polytetrafluoroethylene grafts.

Authors:  Sanjay Misra; Alex A Fu; Khamal D Misra; James F Glockner; Debabrata Mukhopadhyay
Journal:  Angiology       Date:  2009-07-21       Impact factor: 3.619

4.  Numerical modeling of the flow in intracranial aneurysms: prediction of regions prone to thrombus formation.

Authors:  V L Rayz; L Boussel; M T Lawton; G Acevedo-Bolton; L Ge; W L Young; R T Higashida; D Saloner
Journal:  Ann Biomed Eng       Date:  2008-09-12       Impact factor: 3.934

5.  Phase-contrast magnetic resonance imaging measurements in intracranial aneurysms in vivo of flow patterns, velocity fields, and wall shear stress: comparison with computational fluid dynamics.

Authors:  Loic Boussel; Vitaliy Rayz; Alastair Martin; Gabriel Acevedo-Bolton; Michael T Lawton; Randall Higashida; Wade S Smith; William L Young; David Saloner
Journal:  Magn Reson Med       Date:  2009-02       Impact factor: 4.668

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.