Literature DB >> 10050124

Rationalization of incisor shape: experimental-numerical analysis.

P Magne1, A Versluis, W H Douglas.   

Abstract

STATEMENT OF PROBLEM: Moving from the posterior segment in the anterior direction within the dental arch, the process of "incisivization" takes place. The occlusal table is gradually replaced by an incisal edge that has the function of cutting.
PURPOSE: This study considers these genetically controlled changes by using strain gauge measurements and finite element analyses to rationalize the clinical and biologic advantages of incisal form. A direct clinical link in the common esthetic procedure of anterior veneering is expected.
MATERIAL AND METHODS: Six maxillary incisors were mounted in a positioning device and equipped with 2 strain gauges bonded to the palatal surface: gauge 1 (G1) in the concavity and gauge 2 (G2) on the cingulum. A 50 N load was applied on the palatal side of the incisal edge, perpendicular to the long axis of the tooth. Displacement of the load tip and the palatal strain were recorded after successively removing one third, two thirds, and the total thickness of the facial enamel. The same experiment was reproduced with the finite element method (FEM). Four additional experimental designs were tested with the FEM by simulating the progressive thinning and elimination of palatal enamel and a thickened palatal lobe. Surface tangential stresses and local strain in the area corresponding to gauges 1 and 2 were calculated from the postprocessing files.
RESULTS: The FEM was validated by experimental results considering both displacement of the load tip ( approximately 120 +/- 30 microm) and tangential surface strain at G1/G2. Recorded strains were always higher in the concavity when compared with the cingulum; high tensile strains were recorded at G1 after the total removal of the facial enamel. The entire facial surface was submitted to compressive forces. Subsequent compressive stresses were higher ( approximately 150 MPa) when facial enamel was thin or when the palatal enamel was removed. However, their absolute value never reached the elevated and potentially harmful tensile stresses measured in the palatal concavity, especially in the absence of facial enamel (272 MPa). Multiple experimental cracks were generated in the remaining palatal enamel as a consequence of stress redistribution. However, smooth and convex surfaces with local enamel bulk such as the cingulum, the marginal ridges, and the facial cervical third of the anatomic crown showed the lowest stress level. The optimal configuration with regard to the stress pattern was given by the modified natural tooth that exhibited thick palatal enamel and a mostly convex palatal surface.
CONCLUSIONS: Palatal concavity that provides the incisor with its sharp incisal edge and cutting ability proved to be an area of stress concentration. This shortcoming can be compensated by specific areas that feature thick enamel such as the cingulum and the marginal ridges. When enamel is worn or removed from the facial surface, its replacement should be carried out by using materials with properties similar to enamel to restore the original biomechanical behavior of the tooth.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10050124     DOI: 10.1016/s0022-3913(99)70279-9

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  7 in total

1.  An experimentally validated micromechanical model of a rat vertebra under compressive loading.

Authors:  Naomi Tsafnat; Stephen Wroe
Journal:  J Anat       Date:  2010-08-31       Impact factor: 2.610

2.  Conservative restoration of severely damaged endodontically treated premolar teeth: a FEM study.

Authors:  Öznur Eraslan; Oğuz Eraslan; Gürcan Eskitaşcıoğlu; Sema Belli
Journal:  Clin Oral Investig       Date:  2010-03-18       Impact factor: 3.573

3.  The Effect of Framework Design on Stress Distribution in Implant-Supported FPDs: A 3-D FEM Study.

Authors:  Oguz Eraslan; Ozgur Inan; Asli Secilmis
Journal:  Eur J Dent       Date:  2010-10

4.  The finite element analysis of the effect of ferrule height on stress distribution at post-and-core-restored all-ceramic anterior crowns.

Authors:  Oğuz Eraslan; Filiz Aykent; M Tolga Yücel; Serhan Akman
Journal:  Clin Oral Investig       Date:  2008-08-12       Impact factor: 3.573

5.  Structure-function relations of primate lower incisors: a study of the deformation of Macaca mulatta dentition using electronic speckle pattern interferometry (ESPI).

Authors:  Netta Lev-Tov Chattah; Kornelius Kupczik; Ron Shahar; Jean-Jacques Hublin; Steve Weiner
Journal:  J Anat       Date:  2011-01       Impact factor: 2.610

6.  The adaptive significance of enamel loss in the mandibular incisors of cercopithecine primates (Mammalia: Cercopithecidae): a finite element modelling study.

Authors:  Kornelius Kupczik; Netta Lev-Tov Chattah
Journal:  PLoS One       Date:  2014-05-15       Impact factor: 3.240

7.  Evaluation of fracture resistance of ceramic veneers with different preparation designs and loading conditions: An in vitro study.

Authors:  Aman Arora; Viram Upadhyaya; Sheen J Arora; Prachi Jain; Avneet Yadav
Journal:  J Indian Prosthodont Soc       Date:  2017 Oct-Dec
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.