Literature DB >> 20922156

The Effect of Framework Design on Stress Distribution in Implant-Supported FPDs: A 3-D FEM Study.

Oguz Eraslan1, Ozgur Inan, Asli Secilmis.   

Abstract

OBJECTIVES: The biomechanical behavior of the superstructure plays an important role in the functional longevity of dental implants. However, information about the influence of framework design on stresses transmitted to the implants and supporting tissues is limited. The purpose of this study was to evaluate the effects of framework designs on stress distribution at the supporting bone and supporting implants.
METHODS: In this study, the three-dimensional (3D) finite element stress analysis method was used. Three types of 3D mathematical models simulating three different framework designs for implant-supported 3-unit posterior fixed partial dentures were prepared with supporting structures. Convex (1), concave (2), and conventional (3) pontic framework designs were simulated. A 300-N static vertical occlusal load was applied on the node at the center of occlusal surface of the pontic to calculate the stress distributions. As a second condition, frameworks were directly loaded to evaluate the effect of the framework design clearly. The Solidworks/Cosmosworks structural analysis programs were used for finite element modeling/analysis.
RESULTS: The analysis of the von Mises stress values revealed that maximum stress concentrations were located at the loading areas for all models. The pontic side marginal edges of restorations and the necks of implants were other stress concentration regions. There was no clear difference among models when the restorations were loaded at occlusal surfaces. When the veneering porcelain was removed, and load was applied directly to the framework, there was a clear increase in stress concentration with a concave design on supporting implants and bone structure.
CONCLUSIONS: The present study showed that the use of a concave design in the pontic frameworks of fixed partial dentures increases the von Mises stress levels on implant abutments and supporting bone structure. However, the veneering porcelain element reduces the effect of the framework and compensates for design weaknesses.

Entities:  

Keywords:  3-D FEM; Framework design; Implant supported fixed partial denture; Pontic design

Year:  2010        PMID: 20922156      PMCID: PMC2948739     

Source DB:  PubMed          Journal:  Eur J Dent


  17 in total

1.  The effects of dowel design and load direction on dowel-and-core restorations.

Authors:  H S Yang; L A Lang; A Molina; D A Felton
Journal:  J Prosthet Dent       Date:  2001-06       Impact factor: 3.426

Review 2.  Clinical complications of osseointegrated implants.

Authors:  C J Goodacre; J Y Kan; K Rungcharassaeng
Journal:  J Prosthet Dent       Date:  1999-05       Impact factor: 3.426

3.  Stress distribution of inlay-anchored adhesive fixed partial dentures: a finite element analysis of the influence of restorative materials and abutment preparation design.

Authors:  Pascal Magne; Nikolaos Perakis; Urs C Belser; Ivo Krejci
Journal:  J Prosthet Dent       Date:  2002-05       Impact factor: 3.426

4.  Finite element analysis of a glass fibre reinforced composite endodontic post.

Authors:  A Pegoretti; L Fambri; G Zappini; M Bianchetti
Journal:  Biomaterials       Date:  2002-07       Impact factor: 12.479

5.  Finite element analysis of fixed prostheses attached to osseointegrated implants.

Authors:  K R Williams; C J Watson; W M Murphy; J Scott; M Gregory; D Sinobad
Journal:  Quintessence Int       Date:  1990-07       Impact factor: 1.677

6.  The in vitro failure of all-ceramic crowns and the connector area of fixed partial dentures using bilayered ceramic specimens: the influence of core to dentin thickness ratio.

Authors:  Garry J P Fleming; Michelle Dickens; Laura J Thomas; Jonathan J Harris
Journal:  Dent Mater       Date:  2005-12-28       Impact factor: 5.304

7.  Dentin-bonded all-ceramic crowns: current status.

Authors:  F J Burke; A J Qualtrough; R W Hale
Journal:  J Am Dent Assoc       Date:  1998-04       Impact factor: 3.634

8.  18-year longitudinal study of cantilevered fixed restorations.

Authors:  V Decock; K De Nayer; J A De Boever; M Dent
Journal:  Int J Prosthodont       Date:  1996 Jul-Aug       Impact factor: 1.681

9.  A finite element analysis of the human temporomandibular joint.

Authors:  J Chen; L Xu
Journal:  J Biomech Eng       Date:  1994-11       Impact factor: 2.097

10.  The influence of occlusal loading location on stresses transferred to implant-supported prostheses and supporting bone: A three-dimensional finite element study.

Authors:  Gurcan Eskitascioglu; Aslihan Usumez; Mujde Sevimay; Emel Soykan; Elif Unsal
Journal:  J Prosthet Dent       Date:  2004-02       Impact factor: 3.426

View more
  8 in total

1.  Comparison of Stress Distribution in a Maxillary Central Incisor Restored with Two Prefabricated Post Systems with and without Ferrule Using Finite Element Method.

Authors:  Aarti Rajambigai; Arun Kumar; Ramesh Raja
Journal:  J Clin Diagn Res       Date:  2016-09-01

2.  A three-dimension finite element analysis to evaluate the stress distribution in tooth supported 5-unit intermediate abutment prosthesis with rigid and nonrigid connector.

Authors:  Ritesh Modi; Shivani Kohli; K Rajeshwari; Shekhar Bhatia
Journal:  Eur J Dent       Date:  2015 Apr-Jun

3.  Effect of cantilever length on stress distribution around implants in mandibular overdentures supported by two and three implants.

Authors:  Behnaz Ebadian; Ramin Mosharraf; Niloufar Khodaeian
Journal:  Eur J Dent       Date:  2016 Jul-Sep

4.  A biomechanical investigation of mandibular molar implants: reproducibility and validity of a finite element analysis model.

Authors:  Miyuki Omori; Yuji Sato; Noboru Kitagawa; Yuta Shimura; Manabu Ito
Journal:  Int J Implant Dent       Date:  2015-04-28

Review 5.  Prosthetic Consideration in Implant-supported Prosthesis: A Review of Literature.

Authors:  Manga Snigdha Gowd; Thatapudi Shankar; Rajeev Ranjan; Arpita Singh
Journal:  J Int Soc Prev Community Dent       Date:  2017-06-20

6.  Finite element analysis of stress concentration between surface coated implants and non surface coated implants - An in vitro study.

Authors:  Tammineedi Sv Satyanarayana; Rathika Rai; E Subramanyam; T Illango; Vishwabharathi Mutyala; Rajesh Akula
Journal:  J Clin Exp Dent       Date:  2019-08-01

7.  Finite Element Method and Von Mises Investigation on Bone Response to Dynamic Stress with a Novel Conical Dental Implant Connection.

Authors:  Luca Fiorillo; Marco Cicciù; Cesare D'Amico; Rodolfo Mauceri; Giacomo Oteri; Gabriele Cervino
Journal:  Biomed Res Int       Date:  2020-10-07       Impact factor: 3.411

8.  FEM Analysis Applied to OT Bridge Abutment with Seeger Retention System.

Authors:  Gabriele Cervino; Marco Cicciù; Simone Fedi; Dario Milone; Luca Fiorillo
Journal:  Eur J Dent       Date:  2020-08-31
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.