Literature DB >> 10036664

A new filtering algorithm for medical magnetic resonance and computer tomography images.

E Stoll1, C Stern, P Stucki, S Wildermuth.   

Abstract

Inner views of tubular structures based on computer tomography (CT) and magnetic resonance (MR) data sets may be created by virtual endoscopy. After a preliminary segmentation procedure for selecting the organ to be represented, the virtual endoscopy is a new postprocessing technique using surface or volume rendering of the data sets. In the case of surface rendering, the segmentation is based on a grey level thresholding technique. To avoid artifacts owing to the noise created in the imaging process, and to restore spurious resolution degradations, a robust Wiener filter was applied. This filter working in Fourier space approximates the noise spectrum by a simple function that is proportional to the square root of the signal amplitude. Thus, only points with tiny amplitudes consisting mostly of noise are suppressed. Further artifacts are avoided by the correct selection of the threshold range. Afterwards, the lumen and the inner walls of the tubular structures are well represented and allow one to distinguish between harmless fluctuations and medically significant structures.

Mesh:

Year:  1999        PMID: 10036664      PMCID: PMC3452428          DOI: 10.1007/bf03168623

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  6 in total

1.  Virtual endoscopy: is it reality?

Authors:  D J Vining
Journal:  Radiology       Date:  1996-07       Impact factor: 11.105

2.  Detection of colorectal polyps with CT colography: initial assessment of sensitivity and specificity.

Authors:  A K Hara; C D Johnson; J E Reed; D A Ahlquist; H Nelson; R L MacCarty; W S Harmsen; D M Ilstrup
Journal:  Radiology       Date:  1997-10       Impact factor: 11.105

3.  Preliminary assessment of three-dimensional magnetic resonance imaging for various colonic disorders.

Authors:  W Luboldt; P Bauerfeind; P Steiner; M Fried; G P Krestin; J F Debatin
Journal:  Lancet       Date:  1997-05-03       Impact factor: 79.321

Review 4.  Colon cancer: a review of the epidemiology.

Authors:  J D Potter; M L Slattery; R M Bostick; S M Gapstur
Journal:  Epidemiol Rev       Date:  1993       Impact factor: 6.222

Review 5.  Body MR angiography with gadolinium contrast agents.

Authors:  M R Prince
Journal:  Magn Reson Imaging Clin N Am       Date:  1996-02       Impact factor: 2.266

6.  Detection of mass lesions with MR colonography: preliminary report.

Authors:  W Luboldt; P Steiner; P Bauerfeind; P Pelkonen; J F Debatin
Journal:  Radiology       Date:  1998-04       Impact factor: 11.105

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.