Literature DB >> 10029471

The influence of antagonist standardization on wear.

I Krejci1, P Albert, F Lutz.   

Abstract

For differences among materials to be easily detected, low variation in in vitro wear tests is desirable. The working hypothesis of this paper was that antagonists standardized for shape and size and according to materials would show mean values similar to those found in natural, non-standardized cusps, and that standardization would lead to a reduction in mean variation. First, the shapes and sizes of palatal cusps of non-erupted human upper third molars were measured. The cusp cupola was best described by the formula y = 0.001 x2 and was symmetrical around the axis of rotation. Up to 200 microm of the y-axis, this parabola corresponded best to a ball radius of 0.6 mm. Based on this information, standardized antagonists were fabricated from both human enamel and steatite. Wear in the occlusal contact area and the wear of opposing conventional ceramic and fine hybrid composite, respectively, were quantified in a computerized chewing simulator. As a control, natural human enamel cusps were used. Standardization of enamel cusps did not reduce the variation of the resulting wear compared with that of non-standardized enamel antagonists. Furthermore, standardization led to significantly different results both in the antagonists and in the opposing restorative materials. Thus, natural enamel antagonists are preferable for the simulation of wear in the occlusal contact area.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10029471     DOI: 10.1177/00220345990780021201

Source DB:  PubMed          Journal:  J Dent Res        ISSN: 0022-0345            Impact factor:   6.116


  13 in total

1.  Sliding contact fracture of dental ceramics: Principles and validation.

Authors:  Linlin Ren; Yu Zhang
Journal:  Acta Biomater       Date:  2014-03-12       Impact factor: 8.947

2.  Graded zirconia glass for resistance to veneer fracture.

Authors:  Y Zhang; J W Kim
Journal:  J Dent Res       Date:  2010-07-22       Impact factor: 6.116

3.  Graded structures for damage resistant and aesthetic all-ceramic restorations.

Authors:  Yu Zhang; Jae-Won Kim
Journal:  Dent Mater       Date:  2009-02-01       Impact factor: 5.304

4.  Load-bearing properties of minimal-invasive monolithic lithium disilicate and zirconia occlusal onlays: finite element and theoretical analyses.

Authors:  Li Ma; Petra C Guess; Yu Zhang
Journal:  Dent Mater       Date:  2013-05-15       Impact factor: 5.304

5.  Marginal and internal fit of heat pressed versus CAD/CAM fabricated all-ceramic onlays after exposure to thermo-mechanical fatigue.

Authors:  Petra C Guess; Thaleia Vagkopoulou; Yu Zhang; Martin Wolkewitz; Joerg R Strub
Journal:  J Dent       Date:  2013-10-24       Impact factor: 4.379

6.  Damage maps of veneered zirconia under simulated mastication.

Authors:  J-W Kim; J-H Kim; M N Janal; Y Zhang
Journal:  J Dent Res       Date:  2008-12       Impact factor: 6.116

7.  Damage sensitivity of dental zirconias to simulated occlusal contact.

Authors:  Marcia Borba; Tomoyuki K Okamoto; Michelle Zou; Marina R Kaizer; Yu Zhang
Journal:  Dent Mater       Date:  2020-11-21       Impact factor: 5.304

8.  In Vitro Investigation of Wear of CAD/CAM Polymeric Materials Against Primary Teeth.

Authors:  Jae-Won Choi; Eun-Ju Song; Jong-Hyun Shin; Tae-Sung Jeong; Jung-Bo Huh
Journal:  Materials (Basel)       Date:  2017-12-09       Impact factor: 3.623

9.  Influence of CAD/CAM milling, sintering and surface treatments on the fatigue behavior of lithium disilicate glass ceramic.

Authors:  Abdur-Rasheed Alao; Richard Stoll; Yu Zhang; Ling Yin
Journal:  J Mech Behav Biomed Mater       Date:  2020-10-07

10.  Wear of primary teeth caused by opposed all-ceramic or stainless steel crowns.

Authors:  Jae-Won Choi; Ik-Hyun Bae; Tae-Hwan Noh; Sung-Won Ju; Tae-Kyoung Lee; Jin-Soo Ahn; Tae-Sung Jeong; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2016-02-23       Impact factor: 1.904

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.