Literature DB >> 10024069

Anxiety in patients with an automatic implantable cardioverter defibrillator: what differentiates them from panic patients?

P Pauli1, G Wiedemann, W Dengler, G Blaumann-Benninghoff, V Kühlkamp.   

Abstract

OBJECTIVE: Anxiety seems to be a frequent problem in patients with an automatic implantable cardioverter defibrillator (AICD). Distressing experiences before or after AICD implantation such as resuscitation, or AICD shocks are suspected as causes for enhanced anxiety levels. A closer examination of the level and structure of anxiety in AICD patients and a comparison with panic patients might help to examine additionally both conditioning and cognitive models of anxiety.
METHODS: There were 61 AICD patients examined with a specifically designed AICD questionnaire and standardized anxiety and depression questionnaires. Subgroups of AICD patients without, with some, and with definite anxiety related to AICD shocks were compared with panic patients and healthy control subjects.
RESULTS: Although fear of dying was greatly reduced by AICD implantation, approximately one third of the AICD patients, especially patients with definite anxiety related to AICD shocks, were characterized both by enhanced anxiety levels and avoidance behavior. These patients were comparable with panic patients in most questionnaire scores. Anxiety levels were not associated with objective AICD shock experiences or medical variables.
CONCLUSIONS: Anxiety in AICD patients seems to be unrelated to traumatic experiences, a finding that casts doubt on pure conditioning models of anxiety. Presumably, a life-threatening cardiac disorder increases the likelihood for catastrophic interpretations of bodily signs, especially in anxiety prone AICD patients. In accordance with cognitive models of panic disorder, this cognitive dysfunction could lead to anxiety and depression levels comparable with those of panic patients.

Entities:  

Mesh:

Year:  1999        PMID: 10024069     DOI: 10.1097/00006842-199901000-00012

Source DB:  PubMed          Journal:  Psychosom Med        ISSN: 0033-3174            Impact factor:   4.312


  11 in total

Review 1.  Quality of life and psychological functioning of icd patients.

Authors:  Samuel F Sears; Jamie B Conti
Journal:  Heart       Date:  2002-05       Impact factor: 5.994

2.  Psychological indices and phantom shocks in patients with ICD.

Authors:  Liza A Prudente; Juanita Reigle; Cheryl Bourguignon; David E Haines; John P DiMarco
Journal:  J Interv Card Electrophysiol       Date:  2006-08-04       Impact factor: 1.900

Review 3.  Understanding implantable cardioverter defibrillator shocks and storms: medical and psychosocial considerations for research and clinical care.

Authors:  Samuel E Sears; Jamie B Conti
Journal:  Clin Cardiol       Date:  2003-03       Impact factor: 2.882

4.  Longitudinal changes in quality of life following ICD implant and the impact of age, gender, and ICD shocks: observations from the INTRINSIC RV trial.

Authors:  Rakesh Gopinathannair; Darin R Lerew; Natalie J Cross; Samuel F Sears; Scott Brown; Brian Olshansky
Journal:  J Interv Card Electrophysiol       Date:  2017-02-20       Impact factor: 1.900

5.  Cognitive and behavioral treatments for anxiety and depression in a patient with an implantable cardioverter defibrillator (ICD): a case report and clinical discussion.

Authors:  Adam T Hirsh; Samuel F Sears; Jamie B Conti
Journal:  J Clin Psychol Med Settings       Date:  2009-04-30

6.  Panic disorders and agoraphobia: side effects of treatment with an implantable cardioverter/defibrillator.

Authors:  Frank Godemann; Christian Butter; Felix Lampe; Michael Linden; Michael Schlegl; Hans-Peter Schultheiss; Steffen Behrens
Journal:  Clin Cardiol       Date:  2004-06       Impact factor: 2.882

7.  Tetanizing prepulse: A novel strategy to mitigate implantable cardioverter-defibrillator shock-related pain.

Authors:  David W Hunter; Harikrishna Tandri; Henry Halperin; Leslie Tung; Ronald D Berger
Journal:  Heart Rhythm       Date:  2016-01-06       Impact factor: 6.343

Review 8.  Psychological effects of implantable cardioverter defibrillator shocks. A review of study methods.

Authors:  Gian Mauro Manzoni; Gianluca Castelnuovo; Angelo Compare; Francesco Pagnini; Vidal Essebag; Riccardo Proietti
Journal:  Front Psychol       Date:  2015-02-04

9.  Manual for the psychotherapeutic treatment of acute and post-traumatic stress disorders following multiple shocks from implantable cardioverter defibrillator (ICD).

Authors:  Jochen Jordan; Georg Titscher; Ludmila Peregrinova; Holger Kirsch
Journal:  Psychosoc Med       Date:  2013-12-18

10.  Health anxiety and illness-related fears across diverse chronic illnesses: A systematic review on conceptualization, measurement, prevalence, course, and correlates.

Authors:  Sophie Lebel; Brittany Mutsaers; Christina Tomei; Caroline Séguin Leclair; Georden Jones; Danielle Petricone-Westwood; Nicole Rutkowski; Viviane Ta; Geneviève Trudel; Simone Zofia Laflamme; Andrée-Anne Lavigne; Andreas Dinkel
Journal:  PLoS One       Date:  2020-07-27       Impact factor: 3.240