Literature DB >> 999213

Change in hormones reflecting sympathetic activity in the Finnish sauna.

R Lammintausta, E Syvälahti, A Pekkarinen.   

Abstract

The effects of the high temperature (80-120 degrees C) of the Finnish Sauna bath on the concentrations of growth hormone, immunoreactive insulin and renin activity in plasma, on blood glucose and on the urinary excretion of aldosterone, vanilmandelic acid and sodium of 55 healthy volunteers were studied. There was a significant increase in mean heart rate (62%), serum growth hormone (142%) and plasma renin activity (95%) in the Sauna. One hour after the Sauna bath the mean serum growth hormone had returned to the control level while plasma renin activity still remained higher (p less than 0.05) than before the Sauna bath. The serum insulin, blood sugar and urinary excretion of aldosterone and VMA did not change during or after Sauna bath. The urinary sodium excretion decreased significantly after the Sauna bath and the decrease was most striking (46%) during the first 6-hour period from the beginning of Sauna bath. Plasma renin activity values correlated positively with 12-hour urinary VMA excretion (p less than 0.01) and negatively with 6-hour urinary sodium excretion (p less than 0.05) before and after Sauna, suggesting the role of catecholamines and sodium depletion in renin response in Sauna.

Entities:  

Mesh:

Substances:

Year:  1976        PMID: 999213

Source DB:  PubMed          Journal:  Ann Clin Res        ISSN: 0003-4762


  4 in total

1.  Sauna habits and related symptoms in Finnish children.

Authors:  L Markkola; K J Mattila; M J Koivikko
Journal:  Eur J Pediatr       Date:  1989-12       Impact factor: 3.183

2.  Increased glucagon secretion during hyperthermia in a sauna.

Authors:  P Tatár; M Vigas; J Jurcovicová; R Kvetnanský; V Strec
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1986

Review 3.  TRPV1, TRPA1, and TRPM8 channels in inflammation, energy redirection, and water retention: role in chronic inflammatory diseases with an evolutionary perspective.

Authors:  Rainer H Straub
Journal:  J Mol Med (Berl)       Date:  2014-05-29       Impact factor: 4.599

4.  Correlations between Repeated Use of Dry Sauna for 4 x 10 Minutes, Physiological Parameters, Anthropometric Features, and Body Composition in Young Sedentary and Overweight Men: Health Implications.

Authors:  Robert Podstawski; Krzysztof Borysławski; Cain C T Clark; Dariusz Choszcz; Kevin J Finn; Piotr Gronek
Journal:  Biomed Res Int       Date:  2019-01-21       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.