Literature DB >> 9987643

Thickness, taper, and ellipticity in the aortoiliac bifurcation of patients aged 1 day to 76 years.

N F MacLean1, M R Roach.   

Abstract

Lumen area, ellipticity, and wall thickness were measured in the aortoiliac bifurcations obtained at autopsy from 14 patients aged between 1 day and 76 years. The method involved freezing pressure-fixed, stained bifurcations on the stage of a refrigerated microtome and then looking at the block face while sections were removed. Area change was normalized over segment length to produce a value of either taper (narrowing, in mm2/mm), or flare (expansion). The aortoiliac bifurcations were divided into three regions based on the area changes: an apical region corresponding to the bifurcation apex (taper = 2.96 +/- 0.80 mm2/mm), a preapical region (flare = 3.58 +/- 0.87 mm2/mm), and the postapical region (flare = 0.82 +/- 0.80 mm2/mm). Preapical lumen ellipticity showed that the anterio-posterior diameter was always less than the lateral diameter, while the degree of ellipticity increased with age. Average circumferential wall thickness, assessed in polar coordinates, decreased between 0 degree (right lateral) and 120 degrees, while a significant increase in wall thickness was present between 120 degrees and 200 degrees. The most striking difference was found in the 1-day-old, which was very thin posteriorly. This detailed geometric analysis of the aortoiliac bifurcation suggests that taper, flare, and variations in both circumferential and longitudinal wall thickness need to be considered when trying to correlate physical factors in the aorta with the precise location of atherosclerotic lesions and wall remodeling.

Entities:  

Mesh:

Year:  1998        PMID: 9987643     DOI: 10.1007/bf01744592

Source DB:  PubMed          Journal:  Heart Vessels        ISSN: 0910-8327            Impact factor:   2.037


  12 in total

1.  Taper: an important feature of Y-bifurcations in porcine renal arteries and human cerebral arteries.

Authors:  N F MacLean; R G Kratky; T W Macfarlane; M R Roach
Journal:  J Biomech       Date:  1992-09       Impact factor: 2.712

2.  Arterial adaptations to altered blood flow.

Authors:  R D Brownlee; B L Langille
Journal:  Can J Physiol Pharmacol       Date:  1991-07       Impact factor: 2.273

3.  Shear stress regulation of artery lumen diameter in experimental atherogenesis.

Authors:  C K Zarins; M A Zatina; D P Giddens; D N Ku; S Glagov
Journal:  J Vasc Surg       Date:  1987-03       Impact factor: 4.268

4.  The area ration of normal aortic junctions. Aortic configuration and pulse-wave reflection.

Authors:  R G Gosling; D L Newman; N L Bowden; K W Twinn
Journal:  Br J Radiol       Date:  1971-11       Impact factor: 3.039

5.  Distribution of the geometric parameters of human aortic bifurcations.

Authors:  C B Bargeron; G M Hutchins; G W Moore; O J Deters; F F Mark; M H Friedman
Journal:  Arteriosclerosis       Date:  1986 Jan-Feb

6.  Hemodynamics in the abdominal aorta: a comparison of in vitro and in vivo measurements.

Authors:  J E Moore; S E Maier; D N Ku; P Boesiger
Journal:  J Appl Physiol (1985)       Date:  1994-04

7.  A chemical test to determine the end point of EDTA decalcification.

Authors:  D J Seilly
Journal:  Med Lab Sci       Date:  1982-01

8.  Vascular geometry at the abdominal aortic bifurcation.

Authors:  Y T Lee; W F Keitzer; F R Watson; H Liu
Journal:  J Am Med Womens Assoc (1972)       Date:  1982-03

Review 9.  The role of fluid mechanics in the localization and detection of atherosclerosis.

Authors:  D P Giddens; C K Zarins; S Glagov
Journal:  J Biomech Eng       Date:  1993-11       Impact factor: 2.097

10.  Two-dimensional velocity measurements in a pulsatile flow model of the normal abdominal aorta simulating different hemodynamic conditions.

Authors:  E M Pedersen; H W Sung; A C Burlson; A P Yoganathan
Journal:  J Biomech       Date:  1993-10       Impact factor: 2.712

View more
  2 in total

1.  Effects of Geometric Variations on the Buckling of Arteries.

Authors:  Parag Datir; Avione Y Lee; Shawn D Lamm; Hai-Chao Han
Journal:  Int J Appl Mech       Date:  2011-10-05       Impact factor: 3.224

2.  Tortuosity of coronary bifurcation as a potential local risk factor for atherosclerosis: CFD steady state study based on in vivo dynamic CT measurements.

Authors:  M Malvè; A M Gharib; S K Yazdani; G Finet; M A Martínez; R Pettigrew; J Ohayon
Journal:  Ann Biomed Eng       Date:  2014-07-02       Impact factor: 3.934

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.