Literature DB >> 9974063

Cerebral arteriovenous malformations: diagnostic value of echo-enhanced transcranial Doppler sonography compared with angiography.

M M Uggowitzer1, C Kugler, M Riccabona, G E Klein, K Leber, J Simbrunner, F Quehenberger.   

Abstract

BACKGROUND AND
PURPOSE: The purpose of our study was to examine the clinical value of echo-enhanced transcranial power Doppler sonography (EE-TCD), including it ability to assess hemodynamic parameters of the intracranial vasculature, in patients with suspected cerebral arteriovenous malformations (AVMs) and to compare this method with angiography.
METHODS: Sixteen patients with suspected cerebral AVMs were examined with EE-TCD and angiography. As an echo-enhancing agent, SHU 508A (Levovist) was administered intravenously by bolus injection in nine patients and by continuous infusion in seven. Sonograms were reviewed without knowledge of other imaging results and were correlated with angiographic findings.
RESULTS: Angiography showed AVMs in 12 of 16 patients. Eleven lesions were located in the anterior or middle fossa and one was in the posterior fossa. EE-TCD was slightly less sensitive in the detection of AVMs (92%, 11/12 lesions), since in one patient the lacking acoustic window did not allow a transcranial examination. EE-TCD slightly underestimated AVM size compared with angiographic findings but showed feeding arteries with sufficient acoustic properties. In seven patients (58%), angiography revealed a coincidental blood supply from another intracranial or extracranial vessel, which was missed by EE-TCD in all cases. Assessment of peak systolic velocities and resistive indexes resulted in a higher (mean, 191.1 cm/s) and a lower (mean, 45.7%) value, respectively, in the feeding arteries as compared with the contralateral arteries (mean, 101.8 cm/s and 55.6%, respectively). Side-to-side differences were significantly higher in patients with AVMs than in those without a malformation. Signal enhancement was markedly longer with continuous infusion (mean, 520 seconds +/- 28.2) than with bolus injection (mean, 145 seconds +/- 10.5) of the contrast agent.
CONCLUSION: In our limited study group, EE-TCD was a sensitive method for the detection of AVMs, and Levovist proved to be a safe and effective echo-enhancing substance.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 9974063

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  6 in total

1.  Potential of three-dimensional ultrasound in neonatal and paediatric neurosonography.

Authors:  M Riccabona; T R Nelson; C Weitzer; B Resch; D P Pretorius
Journal:  Eur Radiol       Date:  2003-03-06       Impact factor: 5.315

2.  Stabilization of Gas Bubbles Released from Water-Soluble Carbohydrates Using Amphiphilic Compounds: Preparation of Formulations and Acoustic Monitoring of Bubble Lifetime.

Authors:  Lars Hoff; Per A Foss; Knut Dyrstad; Jo Klaveness; Pål Rongved
Journal:  J Surfactants Deterg       Date:  2011-02-13       Impact factor: 1.902

Review 3.  The application of ultrasound in the management of cerebral arteriovenous malformation.

Authors:  Bing Fu; Ji-Zong Zhao; Lan-Bing Yu
Journal:  Neurosci Bull       Date:  2008-12       Impact factor: 5.203

Review 4.  Safety of contrast-enhanced ultrasound in children for non-cardiac applications: a review by the Society for Pediatric Radiology (SPR) and the International Contrast Ultrasound Society (ICUS).

Authors:  Kassa Darge; Frederica Papadopoulou; Aikaterini Ntoulia; Dorothy I Bulas; Brian D Coley; Lynn A Fordham; Harriet J Paltiel; Beth McCarville; Frank M Volberg; David O Cosgrove; Barry B Goldberg; Stephanie R Wilson; Steven B Feinstein
Journal:  Pediatr Radiol       Date:  2013-07-11

5.  The characteristics of transcranial color-coded duplex sonography in children with cerebral arteriovenous malformation presenting with headache.

Authors:  Vlasta Duranovic; Katarina Vulin; Ivana Dakovic; Jasna Lenicek Krleza; Sanja Delin; Ivana Galinovic; Josip Marjanovic; Ana Tripalo Batos; Zdenka Plesa Premilovac; Vlatka Mejaski Bosnjak
Journal:  Childs Nerv Syst       Date:  2017-12-16       Impact factor: 1.475

Review 6.  Editorial review: pediatric 3D ultrasound.

Authors:  Michael Riccabona
Journal:  J Ultrason       Date:  2014-03-30
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.