Effect of flexibility of the femoral stem on bone-remodeling and fixation of the stem in a canine total hip arthroplasty model without cement.

E J Harvey1, J D Bobyn, M Tanzer, G J Stackpool, J J Krygier, S A Hacking.   

Abstract

The purpose of this study was to compare, with regard to fixation of the implant and femoral bone resorption, two fully porous-coated stems of different stiffnesses in a canine total hip arthroplasty model. A bilateral arthroplasty was carried out with insertion of a titanium-alloy stem (which had stiffness properties comparable with those of the canine femur) on one side and with insertion of a composite stem (which was three to fivefold more flexible than the canine femur) on the contralateral side. Eight femora were evaluated at six months and eight, at eighteen months after the operation, to determine the extent of bone ingrowth, periprosthetic cortical area, intracortical porosity, and bone-remodeling. Despite the markedly greater flexibility of the composite stems, no significant difference could be detected (with the numbers available), with regard to the overall degree of femoral stress-shielding, cortical area, or cortical porosity, between these stems and the stiffer, titanium-alloy stems at either time-period. However, the composite stems had less bone ingrowth and more formation of radiopaque lines than did the titanium-alloy stems. At eighteen months, the values for bone ingrowth were 9.7 +/- 5.38 percent (mean and standard deviation) for the composite stems compared with 28.1 +/- 5.31 percent for the titanium-alloy stems (p = 0.003). Furthermore, the histological sections from the femora containing a composite stem showed radiopaque lines indicative of fibrous ingrowth approximately threefold more often than did those from the femora containing a titanium-alloy stem (p = 0.02).

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 9973059

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  6 in total

Review 1.  PEEK biomaterials in trauma, orthopedic, and spinal implants.

Authors:  Steven M Kurtz; John N Devine
Journal:  Biomaterials       Date:  2007-08-07       Impact factor: 12.479

2.  The effect of scaffold macroporosity on angiogenesis and cell survival in tissue-engineered smooth muscle.

Authors:  Christopher M Walthers; Alireza K Nazemi; Shilpy L Patel; Benjamin M Wu; James C Y Dunn
Journal:  Biomaterials       Date:  2014-03-30       Impact factor: 12.479

3.  The biological response to laser-aided direct metal-coated Titanium alloy (Ti6Al4V).

Authors:  T Shin; D Lim; Y S Kim; S C Kim; W L Jo; Y W Lim
Journal:  Bone Joint Res       Date:  2018-06-05       Impact factor: 5.853

4.  Bioactive and antimicrobial macro-/micro-nanoporous selective laser melted Ti-6Al-4V alloy for biomedical applications.

Authors:  Archana Rajendran; Deepak K Pattanayak
Journal:  Heliyon       Date:  2022-03-15

5.  In-vivo study of osseointegration in Prestige LP cervical disc prosthesis.

Authors:  Jigang Lou; Beiyu Wang; Tingkui Wu; Wenjie Wu; Huibo Li; Ziyang Liu; Hao Liu
Journal:  BMC Musculoskelet Disord       Date:  2018-02-07       Impact factor: 2.362

6.  Comparison of Bone Remodeling Between Collum Femoris-Preserving Stems and Ribbed Stems in 1-Stage Bilateral Total Hip Arthroplasty.

Authors:  Zeming Liu; Bo Liu; Sikai Liu; Mengnan Li; Xiao Chen; Yongtai Han
Journal:  Med Sci Monit       Date:  2020-05-15
  6 in total