Literature DB >> 9973054

Load-displacement behavior in a distal radial fracture model. The effect of simulated healing on motion.

S W Wolfe1, M D Lorenze, G Austin, C R Swigart, M M Panjabi.   

Abstract

External fixation of fractures of the distal end of the radius neutralizes external forces and maintains axial alignment during healing. As far as we know, there have been no biomechanical studies of the effects of early removal of the fixator in a partially healed fracture model. The purpose of the present study was to observe the load-displacement behavior of a distal radial fracture model in which we had simulated partial healing by injection of butyl-rubber caulk and augmented this simulated healing with Kirschner-wire fixation. Sixteen fresh-frozen hand-wrist-forearm specimens from cadavera were mounted in mid-rotation in resin pots, and a load was applied. An osteotomy was used to simulate the fracture. Relative motion at the site of the osteotomy was compared, with use of a three-dimensional Optotrak kinematic device, during physiological loading of six constructs with Kirschner-wire transfixion or outrigger fixation. In the experimental group, partial healing was simulated by injection of butyl-rubber caulk into the site of the osteotomy and testing with simulated muscle-loading was performed through a full range of motion of the wrist. No difference could be detected between the relative motion at the osteotomy sites that had been treated with standard fully augmented external fixation and that in the experimental group (p > 0.05). T test analysis revealed that motion was equivalent regardless of whether Kirschner-wire transfixion or outrigger fixation had been used (p = 0.62) and that all of the augmented constructs had significantly less relative motion than all of the nonaugmented constructs (p < 0.001).

Entities:  

Mesh:

Year:  1999        PMID: 9973054     DOI: 10.2106/00004623-199901000-00008

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  2 in total

1.  [External fixation with motion capacity and radius fractures. Methods and results].

Authors:  D Pennig; S Heck; R Möhring
Journal:  Unfallchirurg       Date:  2011-02       Impact factor: 1.000

2.  Calcium phosphate cement augmentation after volar locking plating of distal radius fracture significantly increases stability.

Authors:  Hans Kainz; Enrico Dall'Ara; Anna Antoni; Heinz Redl; Philippe Zysset; Patrick Weninger
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-08-04
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.