Favorable effects of flecainide in transvenous internal cardioversion of atrial fibrillation.

G Boriani1, M Biffi, A Capucci, G Bronzetti, G M Ayers, R Zannoli, A Branzi, B Magnani.   

Abstract

OBJECTIVES: The aim of the study was to evaluate the effects of intravenous (IV) flecainide on defibrillation energy requirements in patients treated with low-energy internal atrial cardioversion.
BACKGROUND: Internal cardioversion of atrial fibrillation is becoming a more widely accepted therapy for acute episode termination and for implantable atrial defibrillators.
METHODS: Twenty-four patients with atrial fibrillation (19 persistent, 5 paroxysmal) underwent elective transvenous cardioversion according to a step-up protocol. After successful conversion in a drug-free state, atrial fibrillation was induced by atrial pacing; IV flecainide (2 mg/kg) was administered and a second threshold was determined. In patients in whom cardioversion in a drug-free state failed notwithstanding a 400- to 550-V shock, a threshold determination was attempted after flecainide.
RESULTS: Chronic persistent atrial fibrillation was converted in 13/19 (68%) patients at baseline and in 16/19 (84%) patients after flecainide. Paroxysmal atrial fibrillation was successfully cardioverted in all the patients. A favorable effect of flecainide was observed either in chronic persistent atrial fibrillation (13 patients) or in paroxysmal atrial fibrillation (5 patients) with significant reductions in energy requirements for effective defibrillation (persistent atrial fibrillation: 4.42+/-1.37 to 3.50+/-1.51 J, p < 0.005; paroxysmal atrial fibrillation: 1.68+/-0.29 to 0.84+/-0.26 J, p < 0.01). In 14 patients not requiring sedation, the favorable effects of flecainide on defibrillation threshold resulted in a significant reduction in the scores of shock-induced discomfort (3.71+/-0.83 vs. 4.29+/-0.61, p < 0.005). No ventricular proarrhythmia was observed for any shock.
CONCLUSIONS: Intravenous flecainide reduces atrial defibrillation threshold in patients treated with low-energy internal atrial cardioversion. This reduction in threshold results in lower shock-induced discomfort. Additionally, flecainide may increase the procedure success rate in patients with chronic persistent atrial fibrillation.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 9973012     DOI: 10.1016/s0735-1097(98)00577-4

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  8 in total

1.  Clinical feasibility of low energy internal atrial cardioversion with a three-electrode configuration in patients with unsuccessful conventional configurations.

Authors:  G Benedini; A Gardini; T Toselli; G Antonioli; G Guardigli; G Saccomanno; M Marini
Journal:  J Interv Card Electrophysiol       Date:  2000-04       Impact factor: 1.900

Review 2.  Internal defibrillation: where we have been and where we should be going?

Authors:  Samuel Lévy
Journal:  J Interv Card Electrophysiol       Date:  2005-08       Impact factor: 1.900

3.  Rate of conversion and recurrence after sotalol treatment in patients with direct current-refractory atrial fibrillation.

Authors:  Anna Nergärdh; Rolf Nordlander; Mats Frick
Journal:  Clin Cardiol       Date:  2006-02       Impact factor: 2.882

Review 4.  Is An Atrial Defibrillator Still An Option In Treating Patients With Atrial Fibrillation?

Authors:  Ziad El Khoury; Deepak Bhakta
Journal:  J Atr Fibrillation       Date:  2013-02-12

5.  Prevention of short term reversible chronic atrial fibrillation by permanent pacing at the triangle of Koch.

Authors:  L Padeletti; M C Porciani; A Michelucci; A Colella; A Costoli; C Ciapetti; P Pieragnoli; N Musilli; G F Gensini
Journal:  J Interv Card Electrophysiol       Date:  2000-12       Impact factor: 1.900

6.  The circadian variation of atrial defibrillation thresholds.

Authors:  Andrew Robert John Mitchell; Eduardo Warman; Katie Schaaf; Neil Sulke
Journal:  J Interv Card Electrophysiol       Date:  2004-02       Impact factor: 1.900

Review 7.  Effect of drugs on defibrillation capacity.

Authors:  Anna Legreid Dopp; John M Miller; James E Tisdale
Journal:  Drugs       Date:  2008       Impact factor: 9.546

Review 8.  Twenty-five years in the making: flecainide is safe and effective for the management of atrial fibrillation.

Authors:  Etienne Aliot; Alessandro Capucci; Harry J Crijns; Andreas Goette; Juan Tamargo
Journal:  Europace       Date:  2010-12-07       Impact factor: 5.214

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.