The effect of halothane on the amplitude and frequency characteristics of heart sounds in children.

G R Manecke1, M A Nemirov, A A Bicker, R N Adsumelli, P J Poppers.   

Abstract

UNLABELLED: Although continuous auscultation has been used during surgery as a monitor of cardiac function for many years, the effect of anesthetics on heart sounds has never been quantified. We determined the root mean squared amplitude and frequency characteristics (peak frequency, spectral edge, and power ratios) of the first (S1) and second (S2) heart sounds in 19 healthy children during induction of anesthesia with halothane. In all patients, halothane decreased the amplitude of S1 (R2 = 0.87 +/- 0.12) and S2 (R2 = 0.66 +/- 0.33) and the high-frequency components (>80 Hz) of these sounds. These changes were clearly audible and preceded decreases in heart rate and blood pressure. The spectral edge decreased for S1 in 18 patients (R2 = 0.73 +/- 0.24) and for S2 in 13 patients (R2 = 0.58 +/- 0.25). Peak frequency did not change. The rapidity with which myocardial depression and its associated changes in heart sound characteristics occurred confirms that continuous auscultation of heart sounds is a useful clinical tool for hemodynamic monitoring of anesthetized infants and children. IMPLICATIONS: Heart sound characteristics can be used to monitor cardiac function during halothane anesthesia in children. The changes occur rapidly and precede noticeable changes in heart rate and blood pressure.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 9972738     DOI: 10.1097/00000539-199902000-00007

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  7 in total

1.  System for simultaneously monitoring heart and breathing rate in mice using a piezoelectric transducer.

Authors:  Shinichi Sato; Katsuya Yamada; Nobuya Inagaki
Journal:  Med Biol Eng Comput       Date:  2006-04-11       Impact factor: 2.602

2.  The Bare Minimum: The Reality of Global Anaesthesia and Patient Safety.

Authors:  Kelly McQueen; Tom Coonan; Andrew Ottaway; Simon Hendel; Paulin R Bagutifils; Alison Froese; Robert Neighbor; Haydn Perndt
Journal:  World J Surg       Date:  2015-09       Impact factor: 3.352

3.  Heart sounds analysis via esophageal stethoscope system in beagles.

Authors:  Sang Hi Park; Young Duck Shin; Jin Ho Bae; Eun Jung Kwon; Tae-Soo Lee; Ji-Yun Shin; Yeong-Cheol Kim; Gyeong-Deuk Min; Myoung hwan Kim
Journal:  J Clin Monit Comput       Date:  2013-03-26       Impact factor: 2.502

4.  Correlation of blood pressure and the ratio of S1 to S2 as measured by esophageal stethoscope and wireless bluetooth transmission.

Authors:  Kyoung Hoon Lim; Young Duck Shin; Sang Hi Park; Jin Ho Bae; Hong Jae Lee; Seon Jung Kim; Ji Yun Shin; Young Jin Choi
Journal:  Pak J Med Sci       Date:  2013-07       Impact factor: 1.088

5.  A Wireless Electronic Esophageal Stethoscope for Continuous Monitoring of Cardiovascular and Respiratory Systems during Anaesthesia.

Authors:  H Parsaei; A Vakily; A M Shafiei
Journal:  J Biomed Phys Eng       Date:  2017-03-01

6.  Arterial pressure changes monitoring with a new precordial noninvasive sensor.

Authors:  Tonino Bombardini; Vincenzo Gemignani; Elisabetta Bianchini; Lucia Venneri; Christina Petersen; Emilio Pasanisi; Lorenza Pratali; Mascia Pianelli; Francesco Faita; Massimo Giannoni; Giorgio Arpesella; Eugenio Picano
Journal:  Cardiovasc Ultrasound       Date:  2008-08-21       Impact factor: 2.062

7.  Beat-to-Beat Tracking of Pulse Pressure and Its Respiratory Variation Using Heart Sound Signal in Patients Undergoing Liver Transplantation.

Authors:  Yong-Seok Park; Young-Jin Moon; Sung-Hoon Kim; Jae-Man Kim; Jun-Gol Song; Gyu-Sam Hwang
Journal:  J Clin Med       Date:  2019-04-30       Impact factor: 4.241

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.