Literature DB >> 9972668

Measurement of red blood cell aggregation in a "plate-plate" shearing system by analysis of light transmission.

O K Baskurt1, H J Meiselman, E Kayar.   

Abstract

The analysis of light reflection from or transmission through a blood sample under defined shearing conditions is widely used to assess red blood cell (RBC) aggregation. Different shearing geometries have been used to generate a constant shear rate within the blood sample, including "cone on plate" and Couette systems. In this study, a rotating glass plate, together with a parallel stationary plate, was used to generate a given shear rate at the point of light transmission measurement. The system gave reproducible results and proved to be sensitive to alterations in RBC aggregation. A comparison between different RBC aggregation parameters that can be calculated using the same light transmission curves (syllectograms) was also made. The index calculated by integrating the area under the syllectogram (M index) was found to be the most appropriate aggregation parameter to be used for comparisons between two groups of blood samples with different aggregation characteristics.

Mesh:

Year:  1998        PMID: 9972668

Source DB:  PubMed          Journal:  Clin Hemorheol Microcirc        ISSN: 1386-0291            Impact factor:   2.375


  6 in total

1.  Wavelength selection in measuring red blood cell aggregation based on light transmittance.

Authors:  Mehmet Uyuklu; Murat Canpolat; Herbert J Meiselman; Oguz K Baskurt
Journal:  J Biomed Opt       Date:  2011-11       Impact factor: 3.170

2.  Velocity variation assessment of red blood cell aggregation with spectral domain Doppler optical coherence tomography.

Authors:  Xiangqun Xu; Lingfeng Yu; Zhongping Chen
Journal:  Ann Biomed Eng       Date:  2010-05-15       Impact factor: 3.934

3.  Photometric measurements of red blood cell aggregation: light transmission versus light reflectance.

Authors:  Oguz K Baskurt; Mehmet Uyuklu; Max R Hardeman; Herbert J Meiselman
Journal:  J Biomed Opt       Date:  2009 Sep-Oct       Impact factor: 3.170

4.  Synthesis, biophysical properties and pharmacokinetics of ultrahigh molecular weight tense and relaxed state polymerized bovine hemoglobins.

Authors:  Paul W Buehler; Yipin Zhou; Pedro Cabrales; Yiping Jia; Guoyong Sun; David R Harris; Amy G Tsai; Marcos Intaglietta; Andre F Palmer
Journal:  Biomaterials       Date:  2010-02-10       Impact factor: 12.479

5.  Microfluidic-based speckle analysis for sensitive measurement of erythrocyte aggregation: A comparison of four methods for detection of elevated erythrocyte aggregation in diabetic rat blood.

Authors:  Eunseop Yeom; Sang Joon Lee
Journal:  Biomicrofluidics       Date:  2015-04-03       Impact factor: 2.800

6.  A rapid and accurate method for estimating the erythrocyte sedimentation rate using a hematocrit-corrected optical aggregation index.

Authors:  Makoto Higuchi; Nobuo Watanabe
Journal:  PLoS One       Date:  2022-07-12       Impact factor: 3.752

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.