Literature DB >> 9952240

Transjugular liver biopsy in 52 patients with an automated Trucut-type needle.

A De Hoyos1, M L Loredo, M A Martínez-Ríos, M R Gil, J Kuri, M Cárdenas.   

Abstract

A three-year prospective study was conducted to assess the efficacy and safety of transjugular liver biopsy with a Trucut-type needle employing an automated device. Fifty-two consecutive patients (39 women and 13 men), ages 46.3+/-14.6 years, in whom percutaneous liver biopsy was contraindicated were included in the study. An 18-gauge transjugular hepatic needle with a 20-mm throw length, a cutting cannula at the distal end, and an automated trigger device on the proximal end was used. All procedures were performed under fluoroscopic control, and the following variables were assessed: (1) number of passes, (2) size and average number of the obtained fragments, (3) number of portal triads, and (4) adequacy of the specimen for histologic diagnosis. The procedure was successful in 49/52 patients, and all samples obtained were satisfactory for histologic analysis even when cirrhosis or bridging fibrosis were present. Mean biopsy specimen length was 1.7+/-0.88 cm; mean number of passes was 2.42+/-1.01, the mean number of biopsy fragments and portal triads per attempt were 2.5+/-1.01 and 6.24+/-3.18, respectively. No major complications were observed. Transjugular hepatic biopsy with this new cutting system is an effective and safe procedure in patients with contraindication for percutaneous liver biopsy.

Entities:  

Mesh:

Year:  1999        PMID: 9952240     DOI: 10.1023/a:1026678806368

Source DB:  PubMed          Journal:  Dig Dis Sci        ISSN: 0163-2116            Impact factor:   3.199


  9 in total

1.  CATHETER BIOPSY. EXPERIMENTAL TECHNIC FOR TRANSVENOUS LIVER BIOPSY.

Authors:  C T DOTTER
Journal:  Radiology       Date:  1964-02       Impact factor: 11.105

Review 2.  Transjugular liver biopsy.

Authors:  J H McAfee; E B Keeffe; R G Lee; J Rösch
Journal:  Hepatology       Date:  1992-04       Impact factor: 17.425

3.  Transjugular liver biopsy with an automated device.

Authors:  M Kardache; P Soyer; M Boudiaf; B Cochand-Priollet; J P Pelage; R Rymer
Journal:  Radiology       Date:  1997-08       Impact factor: 11.105

4.  A 21-year experience with major hemorrhage after percutaneous liver biopsy.

Authors:  D B McGill; J Rakela; A R Zinsmeister; B J Ott
Journal:  Gastroenterology       Date:  1990-11       Impact factor: 22.682

5.  Transjugular liver biopsy.

Authors:  I T Gilmore; R D Bradley; R P Thompson
Journal:  Br Med J       Date:  1977-07-09

6.  A review of transjugular cholangiography.

Authors:  M Weiner; W N Hanafee
Journal:  Radiol Clin North Am       Date:  1970-04       Impact factor: 2.303

7.  Experience with transjugular liver biopsy.

Authors:  H J Bull; I T Gilmore; R D Bradley; J H Marigold; R P Thompson
Journal:  Gut       Date:  1983-11       Impact factor: 23.059

8.  Improved method of transvenous liver biopsy.

Authors:  I T Gilmore; R D Bradley; R P Thompson
Journal:  Br Med J       Date:  1978-07-22

9.  Transvenous liver biopsy: an experience based on 1000 hepatic tissue samplings with this procedure.

Authors:  D Lebrec; G Goldfarb; C Degott; B Rueff; J P Benhamou
Journal:  Gastroenterology       Date:  1982-08       Impact factor: 22.682

  9 in total
  8 in total

Review 1.  Liver biopsy: when, how, by whom, and where?

Authors:  D B McGill
Journal:  Curr Gastroenterol Rep       Date:  2001-02

2.  Transjugular liver biopsy: how good is it for accurate histological interpretation?

Authors:  E Cholongitas; A Quaglia; D Samonakis; M Senzolo; C Triantos; D Patch; G Leandro; A P Dhillon; A K Burroughs
Journal:  Gut       Date:  2006-04-24       Impact factor: 23.059

3.  Emergency transjugular liver biopsies in post-liver-transplant patients: technical success and utility.

Authors:  H Abujudeh; R Huggins; A Patel
Journal:  Emerg Radiol       Date:  2004-01-14

Review 4.  An appraisal of the histopathological assessment of liver fibrosis.

Authors:  R A Standish; E Cholongitas; A Dhillon; A K Burroughs; A P Dhillon
Journal:  Gut       Date:  2006-04       Impact factor: 23.059

5.  The effect of processing on liver biopsy core size.

Authors:  Thomas R Riley; Francesca M Ruggiero
Journal:  Dig Dis Sci       Date:  2008-02-14       Impact factor: 3.199

6.  Comparison of a new aspiration needle device and the Quick-Core biopsy needle for transjugular liver biopsy.

Authors:  Toru Ishikawa; Hiroteru Kamimura; Atsunori Tsuchiya; Tadayuki Togashi; Kouji Watanabe; Kei Seki; Hironobu Ohta; Toshiaki Yoshida; Noriko Ishihara; Tomoteru Kamimura
Journal:  World J Gastroenterol       Date:  2006-10-21       Impact factor: 5.742

7.  Transjugular liver biopsy: results of 97 patients.

Authors:  Halil Dönmez; Güven Kahriman; Nevzat Ozcan; Ertuğrul Mavili; Kemal Deniz
Journal:  Balkan Med J       Date:  2012-06-01       Impact factor: 2.021

8.  Prognostic value of Ishak fibrosis stage: findings from the hepatitis C antiviral long-term treatment against cirrhosis trial.

Authors:  James E Everhart; Elizabeth C Wright; Zachary D Goodman; Jules L Dienstag; John C Hoefs; David E Kleiner; Marc G Ghany; A Scott Mills; S Russell Nash; Sugantha Govindarajan; Thomas E Rogers; Joel K Greenson; Elizabeth M Brunt; Herbert L Bonkovsky; Chihiro Morishima; Heather J Litman
Journal:  Hepatology       Date:  2010-02       Impact factor: 17.425

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.