Literature DB >> 9950968

Increased prevalence of patent foramen ovale in patients with severe chronic obstructive pulmonary disease.

A Soliman1, H Shanoudy, J Liu, D C Russell, N F Jarmukli.   

Abstract

This study was designed to assess the prevalence of patent foramen ovale (PFO) in patients with severe chronic obstructive pulmonary disease (COPD) and the magnitude of any effects of right-to-left interatrial PFO shunting on systemic arterial oxygen desaturation after the Valsalva maneuver. The prevalence of PFO was compared between a group of 20 patients with severe chronic obstructive pulmonary disease (FEV1% <50%; FEV1/FVC <50%) and 20 control subjects (FEV1% >70%; FEV1/FVC >70%) by contrast transesophageal echocardiography during the Valsalva maneuver with simultaneous measurement of systemic arterial oxygen saturation (SaO2) by pulse oximetry. Patients with severe COPD (FEV1 = 27.2% +/- 8.4%; FEV1 /FVC = 44.3% +/- 11.0%) had a significantly higher pulmonary artery systolic pressure (38.3 +/- 7.3 vs 21.0 +/- 2.4 mm Hg; P <.005), higher prevalence of PFO (14/20 = 70% vs 7/20 = 35%; P <.05), and greater systemic arterial desaturation after Valsalva (Sao2 change: -2.6% +/- 1.4% vs -1.1% +/- 0.9%; P <.005) than control subjects. In the severe COPD group, the degree of systemic arterial desaturation after Valsalva in patients with PFO was significantly greater than in patients without PFO (Sao2 change: -3.1% +/- 1.4% vs -1.5% +/- 0. 5%; P <.05). Significant systemic arterial oxygen desaturation was observed after Valsalva in 45% of patients with interatrial PFO shunting and severe COPD. This significantly correlated with the degree of pulmonary hypertension (r = 0.6; P <.05). We conclude (1) that patients with severe COPD have an increased prevalence of PFO and (2) that approximately one half of subjects with severe COPD and PFO demonstrate statistically significant systemic arterial oxygen desaturation after the Valsalva maneuver.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 9950968     DOI: 10.1016/s0894-7317(99)70121-5

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  10 in total

1.  Effect of a patent foramen ovale on pulmonary gas exchange efficiency at rest and during exercise.

Authors:  Andrew T Lovering; Michael K Stickland; Markus Amann; Matthew J O'Brien; John S Hokanson; Marlowe W Eldridge
Journal:  J Appl Physiol (1985)       Date:  2011-03-03

2.  Significance of Patent Foramen Ovale in Patients with GOLD Stage II Chronic Obstructive Pulmonary Disease (COPD).

Authors:  Dario Martolini; Rebecca Tanner; Claire Davey; Mehul S Patel; Davide Elia; Helen Purcell; Paolo Palange; Nicholas S Hopkinson; Michael I Polkey
Journal:  Chronic Obstr Pulm Dis       Date:  2014-09-25

3.  Echocardiographic Follow-Up of Patent Foramen Ovale and the Factors Affecting Spontaneous Closure.

Authors:  Ali Yildirim; Alperen Aydin; Tevfik Demir; Fatma Aydin; Birsen Ucar; Zubeyir Kilic
Journal:  Acta Cardiol Sin       Date:  2016-11       Impact factor: 2.672

4.  PFO and right-to-left shunting in patients with obstructive sleep apnea.

Authors:  Marina Guchlerner; Peter Kardos; Eva Liss-Koch; Jennifer Franke; Nina Wunderlich; Stefan Bertog; Horst Sievert
Journal:  J Clin Sleep Med       Date:  2012-08-15       Impact factor: 4.062

Review 5.  Hypoxic adaptation during development: relation to pattern of neurological presentation and cognitive disability.

Authors:  Fenella J Kirkham; Avijit K Datta
Journal:  Dev Sci       Date:  2006-07

6.  Unexplained hypoxemia in COPD with cardiac shunt.

Authors:  Rino Frizzelli; Corrado Lettieri; Simone Caiola; Linda Maulucci; Claudio Pinzi; Francesco Agostini; Annalisa Frizzelli
Journal:  Respir Med Case Rep       Date:  2022-05-05

7.  Exercise treadmill saline contrast echocardiography for the detection of patent foramen ovale in hypoxia.

Authors:  Brett E Fenster; Andrew M Freeman; Lori Silveira; J Kern Buckner; Douglas Curran-Everett; John D Carroll
Journal:  Int J Cardiovasc Imaging       Date:  2015-08-01       Impact factor: 2.357

Review 8.  Potential Role of Patent Foramen Ovale in Exacerbating Hypoxemia in Chronic Pulmonary Disease.

Authors:  Michael E Layoun; Jamil A Aboulhosn; Jonathan M Tobis
Journal:  Tex Heart Inst J       Date:  2017-06-01

9.  Patent foramen ovale is not associated with hypoxemia in severe chronic obstructive pulmonary disease and does not impair exercise performance.

Authors:  Zarrin F Shaikh; Julia L Kelly; Dinesh Shrikrishna; Manuel de Villa; Michael J Mullen; Nicholas S Hopkinson; Mary J Morrell; Michael I Polkey
Journal:  Am J Respir Crit Care Med       Date:  2014-03-01       Impact factor: 21.405

10.  Unusual cause of hypoxemia after automatic implantable cardioverter-defibrillatorleads extraction.

Authors:  Dinesh Raju; Chandrika Roysam; Rajendra Singh; Stephen C Clark; Christopher Plummer
Journal:  Ann Card Anaesth       Date:  2015 Oct-Dec
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.