Literature DB >> 9949428

Predicting the ideal implant size before enucleation.

S A Kaltreider1, J L Jacobs, M O Hughes.   

Abstract

PURPOSE: This study of volume replacement in anophthalmic sockets compares the volume replaced by the implant and prosthesis with the volume removed from the socket and evaluates A-scan ultrasonography as a tool to predict an ideal implant size before enucleation.
METHODS: In this retrospective study of 59 anophthalmic patients, the volume replaced by the implant and the prosthesis was compared with the volume of the enucleated eye. The volume removed was estimated by calculating the volume of the fellow eye using A-scan ultrasonography. Enophthalmos and superior sulcus deformity were measured and correlated with the percent volume replacement in the anophthalmic sockets.
RESULTS: Greater enophthalmos and superior sulcus deformity were found in patients with less than 100% volume replacement compared with those with 100% or more volume replacement. The axial length determined by A-scan ultrasonography of the fellow eye suggested that a larger implant size should have been placed in 76.3% of those patients with less than 100% volume replacement. Sixty-three percent of adult patients could have received an implant more than 22 mm in diameter to fill 80% of the volume removed at enucleation.
CONCLUSIONS: A-scan ultrasonography of the fellow eye provides a useful tool for predicting the implant size before surgery for optimal volume replacement.

Entities:  

Mesh:

Year:  1999        PMID: 9949428     DOI: 10.1097/00002341-199901000-00009

Source DB:  PubMed          Journal:  Ophthalmic Plast Reconstr Surg        ISSN: 0740-9303            Impact factor:   1.746


  4 in total

1.  Orbital Volume Augmentation with Calcium Hydroxyapatite Filler in Anophthalmic Enophthalmos.

Authors:  Maryam Aletaha; Hossein Salour; Saied Yadegary; Yousef Fekri; Mehdi Tavakoli
Journal:  J Ophthalmic Vis Res       Date:  2017 Oct-Dec

2.  Long-term Surgical Outcomes of the Multi-purpose Conical Porous Synthetic Orbital Implant.

Authors:  Min-Ji Kang; Su-Kyung Jung; Won-Kyung Cho; Ji-Sun Paik; Suk-Woo Yang
Journal:  Korean J Ophthalmol       Date:  2015-09-22

Review 3.  The Anophthalmic Socket - Reconstruction Options.

Authors:  S Schmitzer; C Simionescu; C Alexandrescu; M Burcea
Journal:  J Med Life       Date:  2014

4.  Custom-made artificial eyes using 3D printing for dogs: A preliminary study.

Authors:  So-Young Park; Jeong-Hee An; Hyun Kwon; Seo-Young Choi; Ka-Young Lim; Ho-Hyun Kwak; Kamal Hany Hussein; Heung-Myong Woo; Kyung-Mee Park
Journal:  PLoS One       Date:  2020-11-20       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.