Literature DB >> 9933279

Standardization of carotid ultrasound: a hemodynamic method to normalize for interindividual and interequipment variability.

C Ranke1, A Creutzig, H Becker, H J Trappe.   

Abstract

BACKGROUND AND
PURPOSE: Accurate carotid Doppler examination is an important issue in the light of large endarterectomy trials, but recommended cutoff values for detection of >70% stenosis vary widely. Standardization of diagnostic criteria should consider patient variation and instrument variability.
METHODS: We prospectively analyzed various Doppler parameters in 44 patients undergoing carotid angiography to evaluate whether normalization through individual reference measurements from the common carotid artery or the distal internal carotid artery could improve accuracy. For assessment of interindividual and interequipment variability, we performed repeated measurements of 40 carotid arteries in 21 patients. Two color-coded duplex ultrasound systems were compared for machine variability estimation: Hewlett Packard SONOS 2500 and ATL Ultramark 9 HDI.
RESULTS: Intrastenotic divided by distally recorded mean blood flow velocity (mean velocity ratio) showed the closest correlation with angiography: R2=0.93. Mean velocity ratio >5 was 97% sensitive and 98% specific for detection of >70% carotid stenosis. Intrastenotic blood flow velocities were significantly different between the 2 duplex systems (0.22+/-0.16 versus 0.17+/-0. 11 m/s; P<0.001), whereas mean velocity ratio values did not differ significantly. Interobserver variation expressed as 95% CI for predicted stenosis between 2 observers was 13.6% (peak systolic velocity) and 15.4% (mean velocity ratio).
CONCLUSIONS: A mean velocity ratio using distal reference measurement in the internal carotid artery can normalize for interindividual and interequipment variability.

Entities:  

Mesh:

Year:  1999        PMID: 9933279     DOI: 10.1161/01.str.30.2.402

Source DB:  PubMed          Journal:  Stroke        ISSN: 0039-2499            Impact factor:   7.914


  4 in total

Review 1.  [Angiology update].

Authors:  C Ranke; H J Trappe
Journal:  Med Klin (Munich)       Date:  1999-05-15

2.  A novel method to quantify carotid artery stenosis by Doppler ultrasound: Using the continuity principle.

Authors:  Christopher B Wong; Joseph C Wong
Journal:  Int J Angiol       Date:  2010

3.  Computer vision approach for ultrasound Doppler angle estimation.

Authors:  Ashraf A Saad; Thanasis Loupas; Linda G Shapiro
Journal:  J Digit Imaging       Date:  2008-05-17       Impact factor: 4.056

Review 4.  [Imaging of vessels supplying the brain].

Authors:  S M Schellong; N Abolmaali; B Voigts; C Stelzner
Journal:  Internist (Berl)       Date:  2017-08       Impact factor: 0.743

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.