Literature DB >> 9931838

[Dislocated proximal humerus fracture--results after stabilization with a double plate].

G A Wanner1, J Romero, O Hersche, A Smekal, W Ertel.   

Abstract

Between October 1995 und December 1997, 57 patients with displaced 2-, 3- and 4-part fractures of the proximal humerus were treated by open reduction and internal fixation with two one-third tubular plates which were applied to the anterior and lateral aspect of the proximal humerus. For the follow-up evaluation shoulder function was assessed in 38 patients after an average of 16.8 +/- 4.2 months using the Constant-score: 32% of the patients showed excellent, 37% good, 21% satisfactory, and 10% unsatisfactory results. The high stability of this technique allows intensive physiotherapy in the early post-operative period and early reintegration in activities of daily living.

Entities:  

Mesh:

Year:  1998        PMID: 9931838

Source DB:  PubMed          Journal:  Langenbecks Arch Chir Suppl Kongressbd        ISSN: 0942-2854


  1 in total

1.  Biomechanical evaluation of hybrid double plate osteosynthesis using a locking plate and an inverted third tubular plate for the treatment of proximal humeral fractures.

Authors:  Jan Theopold; Stefan Schleifenbaum; Mirijam Müller; Michael Werner; Niels Hammer; Christoph Josten; Pierre Hepp
Journal:  PLoS One       Date:  2018-10-29       Impact factor: 3.240