Literature DB >> 9930438

Cardiopulmonary response to maximal exercise in young athletes following the Ross procedure.

J H Oury1, D B Doty, J D Oswalt, J F Knapp, S K Mackey, C M Duran.   

Abstract

BACKGROUND: Aortic prosthetic devices offer limitations that make them less than optimal valve substitutes because the vast majority are innately obstructive, especially at increased levels of hemodynamic function. The present study is designed to demonstrate the hemodynamics of the pulmonary autograft in 11 conditioned athletes who have undergone the Ross (pulmonary autograft) procedure. Data was compared to a group of 13 age-matched "normal athletes."
METHODS: All the Ross athletes had undergone the autograft procedure using the root replacement technique and were at least 3 months into their postrecovery phase. All athletes (both normal and Ross) underwent resting transthoracic echo followed by maximal exercise stress test (modified Bruce protocol) to exhaustion. Post-operative transesphogeal echocardiogram obtained within 90 seconds documented aortic valve gradient and velocity across the aortic valve.
RESULTS: In the Ross athlete group, maximum heart rate was 188 beats per minute, peak aortic valve gradient at rest (mm Hg) 7.69 (mean), velocity across the aortic valve at rest (cm per second) 129.40 (mean), peak aortic valve gradient at maximal exercise (mm Hg) 16.30 (mean), velocity across the aortic valve at maximal exercise (cm per second) 190.00 (mean). In the normal athlete group, maximum heart rate was 176 beats/minute, peak aortic valve gradient at rest (mm Hg) 5.97 (mean), velocity across the aortic valve at rest (cm per second) 120.54 (mean), peak aortic valve gradient at maximal exercise (mm Hg) 14.61 (mean), velocity across the aortic valve at maximal exercise (cm per second) 190.23 (mean).
CONCLUSION: The pulmonary autograft exhibits hemodynamic characteristics similar to the normal human aortic valve under conditions of enhanced cardiac output.

Entities:  

Mesh:

Year:  1998        PMID: 9930438     DOI: 10.1016/s0003-4975(98)01029-7

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  5 in total

1.  Screening for proximal coronary artery anomalies with 3-dimensional MR coronary angiography.

Authors:  Niek H Prakken; Maarten J Cramer; Marlon A Olimulder; Pierfrancesco Agostoni; Willem P Mali; Birgitta K Velthuis
Journal:  Int J Cardiovasc Imaging       Date:  2010-03-26       Impact factor: 2.357

2.  Valvular endothelial cells and the mechanoregulation of valvular pathology.

Authors:  Jonathan T Butcher; Robert M Nerem
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  2007-08-29       Impact factor: 6.237

3.  Serial exercise performance in children with surgically corrected congenital aortic stenosis.

Authors:  B M Mitchell; J F Strasburger; J E Hubbard; H U Wessel
Journal:  Pediatr Cardiol       Date:  2003-03-14       Impact factor: 1.655

4.  Blunt trauma to large vessels: a mathematical study.

Authors:  Rovshan M Ismailov; Nikolai A Shevchuk; Joseph Schwerha; Lawrence Keller; Higmat Khusanov
Journal:  Biomed Eng Online       Date:  2004-05-21       Impact factor: 2.819

5.  Inclusion cylinder method for aortic valve replacement utilising the Ross operation in adults with predominant aortic stenosis - 99% freedom from re-operation on the aortic valve at 15 years.

Authors:  Peter D Skillington; M Mostafa Mokhles; William Wilson; Leeanne Grigg; Marco Larobina; Michael O'Keefe; Johanna Takkenberg
Journal:  Glob Cardiol Sci Pract       Date:  2013-12-30
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.