Literature DB >> 9924173

Intravascular ultrasound and stent implantation: intraobserver and interobserver variability.

E Blessing1, D Hausmann, M Sturm, H G Wolpers, I Amende, A Mügge.   

Abstract

BACKGROUND: Intravascular ultrasound (IVUS) imaging can be used to optimize implantation of intracoronary stents; the variability of the measurements, however, remains unclear. Our aim in this study was to determine the intraobserver and interobserver variability of IVUS measurements after stent implantation.
METHODS: Ninety-four patients underwent implantation of 100 Palmaz-Schatz stents in 98 lesions (79 de novo and 19 restenotic). IVUS measurements (3.5F, 30 MHz) of proximal and distal reference sections and of the smallest stent lumen were performed by 2 investigators.
RESULTS: Intraobserver and interobserver correlations, respectively, were r = 0.96 and 0.93 for the proximal reference, r = 0.94 and 0.92 for the distal reference, and r = 0.97 and 0.97 for minimal stent lumen. Stent expansion (minimal lumen in the stent/mean reference area) showed a variability of r = 0.80 and 0.70. Taking a cutoff point of 90% for adequacy of stent expansion, observers agreed in only 77% whether the stent was adequately or inadequately expanded.
CONCLUSIONS: IVUS enables reproducible lumen measurements in stents and reference sections. The degree of stent expansion, however, underlies a high measurement variability that can lead to different therapeutic strategies.

Entities:  

Mesh:

Year:  1999        PMID: 9924173     DOI: 10.1053/hj.1999.v137.93032

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  3 in total

1.  Multi-laboratory inter-institute reproducibility study of IVOCT and IVUS assessments using published consensus document definitions.

Authors:  Edouard Gerbaud; Giora Weisz; Atsushi Tanaka; Manabu Kashiwagi; Takehisa Shimizu; Lin Wang; Christiano Souza; Brett E Bouma; Melissa J Suter; Milen Shishkov; Giovanni J Ughi; Elkan F Halpern; Mireille Rosenberg; Sergio Waxman; Jeffrey W Moses; Gary S Mintz; Akiko Maehara; Guillermo J Tearney
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2015-09-15       Impact factor: 6.875

Review 2.  Intravascular ultrasound: principles and cerebrovascular applications.

Authors:  H Zacharatos; A E Hassan; A I Qureshi
Journal:  AJNR Am J Neuroradiol       Date:  2010-02-04       Impact factor: 3.825

3.  Stent edge vascular response and in-stent geometry after aerobic exercise.

Authors:  Maria Dalen Taraldsen; Vibeke Videm; Knut Hegbom; Rune Wiseth; Erik Madssen
Journal:  Cardiovasc Interv Ther       Date:  2020-03-09
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.