Literature DB >> 992255

New insertion technique in colonoscopy, forming N-loop and using a stiffening cord.

M Tada, S Takemura, F Misaki, K Kawai.   

Abstract

New insertion technique in colonoscopy with a middle length colonscope which is easy to be handled and without guidance of fluoroscopy was reported. Forming a small N-loop at the sigmoid colon, it was easy to pass the sigmoid colon where is one of the most difficult points to pass through. Further, using a differing cord, the sigmoid colon and the transverse colon were easily straightened and no more loop was seen. With this technique, ileocecal area was observed in 26 of 30 cases (86.7%) and its average time for the insertion required only 17.4 minutes. Therefore, with this technique ,it is emphasized that we can easily observed almost all parts of the colonic mucosa and also terminal ileum without the fluoroscopic control.

Entities:  

Mesh:

Year:  1976        PMID: 992255     DOI: 10.1007/bf02777705

Source DB:  PubMed          Journal:  Gastroenterol Jpn        ISSN: 0435-1339


  3 in total

1.  Endoscopy of the ileocecal area.

Authors:  K Nagasako; T Takemoto
Journal:  Gastroenterology       Date:  1973-09       Impact factor: 22.682

2.  Cancer of the colon, rectum, and anus: a review of 2313 cases.

Authors:  K W Falterman; C B Hill; J C Markey; J W Fox; I Cohn
Journal:  Cancer       Date:  1974-09       Impact factor: 6.860

3.  On the dye spraying method in colonofiberscopy.

Authors:  M Tada; S Katoh; Y Kohli; K Kawai
Journal:  Endoscopy       Date:  1977-05       Impact factor: 10.093

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.