Literature DB >> 9918970

Quantitative angiographic assessment of coronary anastomoses performed without cardiopulmonary bypass.

N C Poirier1, M Carrier, J Lespérance, G Côté, M Pellerin, L P Perrault, L C Pelletier.   

Abstract

BACKGROUND: The quality of the anastomosis performed during coronary artery bypass grafting without cardiopulmonary bypass is a current concern, and myocardial wall restraining devices have been designed to optimize results. A quantitative angiographic analysis was performed to assess coronary anastomoses performed on beating hearts.
METHODS: We studied 34 patients who underwent coronary artery bypass grafting without cardiopulmonary bypass between February 1996 and April 1997. The left internal thoracic artery was anastomosed to the left anterior descending coronary artery in all patients. Coronary angiograms were performed 4 +/- 2 days after the operation. The diameter of the anastomoses was quantified by computer-assisted analysis of grafts and native coronary arteries at the toe and heel of the anastomosis.
RESULTS: Five of the patients who underwent coronary artery bypass without a stabilizer (n = 20) had stenoses of the internal thoracic artery grafted to the left anterior descending coronary artery of more than 50% at the level of the anastomosis proper, 3 had stenoses at the heel of the coronary anastomosis, and 5 had stenoses at the toe. One of the patients in whom a stabilizer was used (n = 14) had a stenosis of more than 50% at the anastomosis, and 1 had stenosis at the heel. Eight patients in whom the anastomoses were performed without stabilization (8/20, 40%) had stenoses of more than 50%, whereas there was only 1 stenosis of more than 50% of coronary luminal diameter among the patients in whom the operation was performed with a stabilizer (P =.02).
CONCLUSION: The quantitative angiographic evaluation suggests that left internal thoracic artery graft to left anterior descending coronary artery anastomoses have a lesser degree of intraluminal stenosis when performed with the use of a myocardial wall stabilizer.

Entities:  

Mesh:

Year:  1999        PMID: 9918970     DOI: 10.1016/S0022-5223(99)70425-3

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  3 in total

1.  Combined coronary artery and abdominal aortic surgery without cardiopulmonary bypass.

Authors:  R Ascione; G Iannelli; N Spampinato
Journal:  Tex Heart Inst J       Date:  2000

2.  Activation of coagulation and fibrinolysis during coronary artery bypass grafting: a comparison between on-pump and off-pump techniques.

Authors:  Shreosee Roy; Kaushik Saha; Krishnendu Mukherjee; Santanu Dutta; Debasis Mukhopadhyay; Indranil Das; Gargi Raychaudhuri
Journal:  Indian J Hematol Blood Transfus       Date:  2013-04-26       Impact factor: 0.900

3.  Comparison of off-pump and on-pump coronary artery bypass grafting in midterm results.

Authors:  Michiko Ishida; Junjiro Kobayashi; Osamu Tagusari; Ko Bando; Kazuo Niwaya; Hiroyuki Nakajima; Satsuki Fukushima; Soichiro Kitamura
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2004-05
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.