Literature DB >> 9916317

Protein variant separations by cation-exchange chromatography on tentacle-type polymeric stationary phases.

M Weitzhandler1, D Farnan, J Horvath, J S Rohrer, R W Slingsby, N Avdalovic, C Pohl.   

Abstract

We developed a set of prototype cation-exchange column packings that are based on a hydrophilic coated, pellicular polymeric support with a grafted tentacular surface chemistry that is highly suited to resolving closely related protein variants. These column packings (1) afford minimal band spreading in conjunction with extremely high selectivity, (2) exhibit a very hydrophilic character and (3) have moderate loading capacity. Cytochrome c variants (bovine, horse, rabbit) were baseline-separated, as was native ribonuclease A and its two deamidation products, the Asp67 and isoAsp67 forms. Humanized monoclonal antibody variants differing in the presence of lysine at the C terminus of the heavy chains were baseline-resolved. Finally, the separation of hemoglobin variants found in a sample containing elevated levels of glycated hemoglobin was also demonstrated.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9916317     DOI: 10.1016/s0021-9673(98)00521-4

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  5 in total

1.  Elucidation of degradants in acidic peak of cation exchange chromatography in an IgG1 monoclonal antibody formed on long-term storage in a liquid formulation.

Authors:  Sejal Gandhi; Da Ren; Gang Xiao; Pavel Bondarenko; Christopher Sloey; Margaret Speed Ricci; Sampathkumar Krishnan
Journal:  Pharm Res       Date:  2011-08-16       Impact factor: 4.200

Review 2.  Chromatographic analysis of the acidic and basic species of recombinant monoclonal antibodies.

Authors:  Yi Du; Alison Walsh; Robin Ehrick; Wei Xu; Kimberly May; Hongcheng Liu
Journal:  MAbs       Date:  2012-07-23       Impact factor: 5.857

3.  Comparative analytical profiling of bevacizumab biosimilars marketed in India: a national control laboratory study.

Authors:  Anu Prakash; Nripendra N Mishra; Utpreksha Vaish; Sonia Sharma; Apoorva Anand; Richi V Mahajan; J P Prasad; Subhash Chand
Journal:  3 Biotech       Date:  2020-11-09       Impact factor: 2.406

4.  Comparison of multiple red cell volume methods performed concurrently in premature infants following allogeneic transfusion.

Authors:  Demet Nalbant; Prasad Bhandary; Nell I Matthews; Robert L Schmidt; Anna Bogusiewicz; Gretchen A Cress; M Bridget Zimmerman; Ronald G Strauss; Donald M Mock; John A Widness
Journal:  Pediatr Res       Date:  2013-09-03       Impact factor: 3.756

5.  Charge variant native mass spectrometry benefits mass precision and dynamic range of monoclonal antibody intact mass analysis.

Authors:  Aaron O Bailey; Guanghui Han; Wilson Phung; Paul Gazis; Jennifer Sutton; Jonathan L Josephs; Wendy Sandoval
Journal:  MAbs       Date:  2018-10-19       Impact factor: 5.857

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.