Literature DB >> 9895091

Fiberoptic-guided airway exchange of the esophageal-tracheal Combitube in spontaneously breathing versus mechanically ventilated patients.

L A Gaitini1, S J Vaida, M Somri, M Fradis, B Ben-David.   

Abstract

UNLABELLED: The aim of this study was to compare fiberoptic-guided airway exchange of the esophageal-tracheal Combitube (ETC, Kendall-Sheridan Catheter Corp., Argyle, NY) with an endotracheal tube in spontaneously breathing versus mechanically ventilated patients. Forty patients with Mallampati score III and IV scheduled for elective surgery were randomly allocated into two groups (n = 20 each): nonparalyzed, spontaneously breathing or paralyzed, mechanically ventilated patients. After anesthetic induction and insertion of the ETC, a fiberoptic bronchoscope threaded into an armored endotracheal tube was passed transnasally into the larynx. Endotracheal intubation was successful in 18 spontaneously breathing patients and in 15 patients during controlled ventilation. Successful airway exchange was completed in significantly less time (P < 0.05) in spontaneously breathing patients (9+/-3 min; mean +/- SD) than in mechanically ventilated patients (13+/-4 min). Both methods allowed for continuous airway control and maintenance of ventilation and oxygenation. The described method is a means of replacing the ETC with an endotracheal tube without interruption of airway control or ventilation. Replacing the ETC with an endotracheal tube using this method is more readily accomplished during spontaneous ventilation than during controlled ventilation. IMPLICATIONS: We describe the replacement of the Combitube by an endotracheal tube by the aid of fiberoptic bronchoscopy and without interruption of airway control or ventilation. The performance of this technique was facilitated by spontaneous ventilation compared with mechanical ventilation.

Entities:  

Mesh:

Year:  1999        PMID: 9895091     DOI: 10.1097/00000539-199901000-00036

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  4 in total

1.  [Unexpected expectable difficult airway : every anesthesia is different].

Authors:  A Schneider; B Grosse-Ophoff; B W Böttiger
Journal:  Anaesthesist       Date:  2010-05       Impact factor: 1.041

Review 2.  Current status of the EasyTube: a review of the literature.

Authors:  Sonia J Vaida; Luis A Gaitini; Michael Frass; Jansie Prozesky
Journal:  Rom J Anaesth Intensive Care       Date:  2015-04

3.  Evaluation of the oesophageal-tracheal double-lumen tube (Combitube) during general anaesthesia.

Authors:  Werner Rabitsch; Peter Krafft; Franz X Lackner; Reinhard Frenzer; Roland Hofbauer; Camillo Sherif; Michael Frass
Journal:  Wien Klin Wochenschr       Date:  2004-02-16       Impact factor: 1.704

4.  Trachlight-guided intubation with esophageal combitube in situ.

Authors:  Rajesh Mahajan; Daljit Singh Charak; Rishab Bassi; Firdose Shafi
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2012-10