Comparison of airway pressure-triggered and airflow-triggered ventilation in very immature infants.

G Dimitriou1, A Greenough, B Laubscher, N Yamaguchi.   

Abstract

Failure of patient-triggered ventilation in very immature infants may be due to the use of inappropriate triggering systems. Two types of airflow trigger were therefore compared consecutively to an airway pressure (SLE) triggering system. Each comparison was made in 10 infants, < or =28 weeks of gestation. Comparison was made of the delivered volume, trigger performance and blood gases using each system for 1 h. Both comparisons showed that the airflow triggering systems performed better: one (Draeger Babylog 8000) had a higher sensitivity (p < 0.01) and the other (Bird VIP airflow trigger), in which inflation was terminated by sensing a reduction in inspiratory flow, had a lower degree of asynchrony (p < 0.01) and a tendency to deliver higher volumes. These results suggest that triggering systems sensing airflow changes may be superior to those sensing airway pressure changes in very immature infants. The use of a mechanism to synchronize the termination of inflation to the end of the patient's inspiration may offer further advantages.

Entities:  

Mesh:

Year:  1998        PMID: 9894826     DOI: 10.1080/080352598750030942

Source DB:  PubMed          Journal:  Acta Paediatr        ISSN: 0803-5253            Impact factor:   2.299


  8 in total

Review 1.  Update on modalities of mechanical ventilators.

Authors:  A Greenough
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2002-07       Impact factor: 5.747

2.  International randomised controlled trial of patient triggered ventilation in neonatal respiratory distress syndrome.

Authors:  J H Baumer
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2000-01       Impact factor: 5.747

Review 3.  New modes of mechanical ventilation in the preterm newborn: evidence of benefit.

Authors:  Nelson Claure; Eduardo Bancalari
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2007-09-05       Impact factor: 5.747

4.  Neurally adjusted ventilatory assist and pressure support ventilation in small species and the impact of instrumental dead space.

Authors:  Francesca Campoccia Jalde; Abdul Raoof Almadhoob; Jennifer Beck; Arthur S Slutsky; Michael S Dunn; Christer Sinderby
Journal:  Neonatology       Date:  2009-11-04       Impact factor: 4.035

5.  Comparison of different inspiratory triggering settings in automated ventilators during cardiopulmonary resuscitation in a porcine model.

Authors:  Dingyu Tan; Jun Xu; Shihuan Shao; Yangyang Fu; Feng Sun; Yazhi Zhang; Yingying Hu; Joseph Walline; Huadong Zhu; Xuezhong Yu
Journal:  PLoS One       Date:  2017-02-10       Impact factor: 3.240

Review 6.  Neurally adjusted ventilatory assist compared to other forms of triggered ventilation for neonatal respiratory support.

Authors:  Thomas E Rossor; Katie A Hunt; Sandeep Shetty; Anne Greenough
Journal:  Cochrane Database Syst Rev       Date:  2017-10-27

Review 7.  Synchronized mechanical ventilation for respiratory support in newborn infants.

Authors:  Anne Greenough; Thomas E Rossor; Adesh Sundaresan; Vadivelam Murthy; Anthony D Milner
Journal:  Cochrane Database Syst Rev       Date:  2016-09-01

Review 8.  Challenges for the development of alternative low-cost ventilators during COVID-19 pandemic in Brazil.

Authors:  Erica Aranha Suzumura; Ana Denise Zazula; Henrique Takachi Moriya; Cristina Quemelo Adami Fais; Alembert Lino Alvarado; Alexandre Biasi Cavalcanti; Ricardo Goulart Rodrigues
Journal:  Rev Bras Ter Intensiva       Date:  2020 Jul-Sep
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.