Literature DB >> 9892769

The four-chamber view and its sensitivity in detecting congenital heart defects.

C O Fernandez1, C Ramaciotti, L B Martin, D M Twickler.   

Abstract

We sought to determine the sensitivity of detecting congenital heart defects with routine antenatal ultrasound including the four-chamber view in a population at low risk for cardiac anomalies. Neonatal outcome and anomaly databases were reviewed to identify cases of morphologic cardiac defects from 1988-1992. Of 176 cases identified, 62 (35%) had routine antenatal ultrasound including the four-chamber view. Thirteen of these 62 (21%) were diagnosed by ultrasound and 18 of the 116 (15%) total defects present were seen. Of these, only 16 of 25 (64%) defects reasonably expected to be seen by the four-chamber cardiac view alone were detected. The routine ultrasound four-chamber cardiac evaluation is limited and detection depends on the type of cardiac defect present.

Entities:  

Mesh:

Year:  1998        PMID: 9892769     DOI: 10.1159/000006844

Source DB:  PubMed          Journal:  Cardiology        ISSN: 0008-6312            Impact factor:   1.869


  5 in total

1.  A novel algorithm for comprehensive fetal echocardiography using 4-dimensional ultrasonography and tomographic imaging.

Authors:  Jimmy Espinoza; Juan Pedro Kusanovic; Luís F Gonçalves; Jyh Kae Nien; Sonia Hassan; Wesley Lee; Roberto Romero
Journal:  J Ultrasound Med       Date:  2006-08       Impact factor: 2.153

2.  Four-chamber view and 'swing technique' (FAST) echo: a novel and simple algorithm to visualize standard fetal echocardiographic planes.

Authors:  L Yeo; R Romero; C Jodicke; G Oggè; W Lee; J P Kusanovic; E Vaisbuch; S Hassan
Journal:  Ultrasound Obstet Gynecol       Date:  2011-03-02       Impact factor: 7.299

3.  Variation in Prenatal Diagnosis of Congenital Heart Disease in Infants.

Authors:  Michael D Quartermain; Sara K Pasquali; Kevin D Hill; David J Goldberg; James C Huhta; Jeffrey P Jacobs; Marshall L Jacobs; Sunghee Kim; Ross M Ungerleider
Journal:  Pediatrics       Date:  2015-08       Impact factor: 7.124

4.  Four-dimensional ultrasonography of the fetal heart using a novel Tomographic Ultrasound Imaging display.

Authors:  Luís F Gonçalves; Jimmy Espinoza; Roberto Romero; Juan Pedro Kusanovic; Betsy Swope; Jyh Kae Nien; Offer Erez; Eleazar Soto; Marjorie C Treadwell
Journal:  J Perinat Med       Date:  2006       Impact factor: 1.901

5.  Performance of different scan protocols of fetal echocardiography in the diagnosis of fetal congenital heart disease: a systematic review and meta-analysis.

Authors:  Yifei Li; Yimin Hua; Jie Fang; Chuan Wang; Lina Qiao; Chaomin Wan; Dezhi Mu; Kaiyu Zhou
Journal:  PLoS One       Date:  2013-06-04       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.