Literature DB >> 988891

Pressure monitoring devices. Overlooked source of nosocomial infection.

R A Weinstein, W E Stamm, L Kramer, L Corey.   

Abstract

Contaminated pressure monitoring devices recently have been implicated as a source of epidemic organisms in three outbreaks of nosocomial bacteremia, one outbreak of candidemia, and one outbreak of hepatitis. Measures necessary to prevent monitoring-related infections have not always been appreciated or taken. As a minimum, pressure monitoring devices should be sterilized between use with different patients; strict aseptic technique should be employed when setting up and using monitoring systems; and each patient's monitoring tubing, fluid, and monitoring devices should be changed at regular intervals.

Entities:  

Mesh:

Year:  1976        PMID: 988891     DOI: 10.1001/jama.236.8.936

Source DB:  PubMed          Journal:  JAMA        ISSN: 0098-7484            Impact factor:   56.272


  13 in total

1.  Oerskovia turbata and Comamonas acidovorans bacteremia in a patient with AIDS.

Authors:  M I Lair; S Bentolila; D Grenet; P Cahen; P Honderlick
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1996-05       Impact factor: 3.267

2.  Single-source outbreak of Candida tropicalis complicating coronary bypass surgery.

Authors:  H D Isenberg; V Tucci; F Cintron; C Singer; G S Weinstein; D H Tyras
Journal:  J Clin Microbiol       Date:  1989-11       Impact factor: 5.948

3.  Nosocomial infections associated with long-term radial artery cannulation.

Authors:  O Leroy; V Billiau; C Beuscart; C Santre; C Chidiac; C Ramage; Y Mouton
Journal:  Intensive Care Med       Date:  1989       Impact factor: 17.440

Review 4.  Central venous catheter infections: concepts and controversies.

Authors:  C R Reed; C N Sessler; F L Glauser; B A Phelan
Journal:  Intensive Care Med       Date:  1995-02       Impact factor: 17.440

5.  O serotyping scheme for Enterobacter cloacae.

Authors:  M A Gaston; C Bucher; T L Pitt
Journal:  J Clin Microbiol       Date:  1983-11       Impact factor: 5.948

6.  Candida parapsilosis fungemia associated with parenteral nutrition and contaminated blood pressure transducers.

Authors:  J J Weems; M E Chamberland; J Ward; M Willy; A A Padhye; S L Solomon
Journal:  J Clin Microbiol       Date:  1987-06       Impact factor: 5.948

7.  Recurrent intravascular-catheter-related bacteremia caused by Delftia acidovorans in a hemodialysis patient.

Authors:  Kobkul Chotikanatis; Martin Bäcker; Gabriela Rosas-Garcia; Margaret R Hammerschlag
Journal:  J Clin Microbiol       Date:  2011-07-20       Impact factor: 5.948

8.  Delftia acidovorans as an Unusual Causative Organism in Line-Related Sepsis.

Authors:  K J Lang; T Chinzowu; K J Cann
Journal:  Indian J Microbiol       Date:  2011-08-10       Impact factor: 2.461

9.  Endocarditis associated with Comamonas acidovorans.

Authors:  H Horowitz; S Gilroy; S Feinstein; G Gilardi
Journal:  J Clin Microbiol       Date:  1990-01       Impact factor: 5.948

10.  Pressure transducers: an overlooked source of sepsis in the intensive care unit.

Authors:  T A Hekker; W van Overhagen; A J Schneider
Journal:  Intensive Care Med       Date:  1990       Impact factor: 17.440

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.