Literature DB >> 9887127

Regional deposition and retention of particles in shallow, inhaled boluses: effect of lung volume.

W D Bennett1, G Scheuch, K L Zeman, J S Brown, C Kim, J Heyder, W Stahlhofen.   

Abstract

The regional deposition of particles in boluses delivered to shallow lung depths and their subsequent retention in the airways may depend on the lung volume at which the boluses are delivered. To evaluate the effect of end-inspiratory lung volume on aerosol bolus delivery, we had healthy subjects inhale radiolabeled, monodisperse aerosol (99mTc-iron oxide, 3.5-microm mass median aerodynamic diameter) boluses (40 ml) to a volumetric front depth of 70 ml into the lung at lung volumes of 50, 70, and 85% of total lung capacity (TLC) end inhalation. By gamma camera analysis, we found significantly greater deposition in the left (L) vs. right (R) lungs at the 70 and 85% TLC end inhalation; ratio of deposition in L to R lung, normalized to L-to-R ratio of lung volume (mean L/R), was 1.60 +/- 0.45 (SD) and 1. 96 +/- 0.72, respectively (P < 0.001 for comparison to 1.0) for posterior images. However, at 50% TLC, L/R was 1.23 +/- 0.37, not significantly different from 1.0. These data suggest that the L and R lungs may be expanding nonuniformly at higher lung volumes. On the other hand, subsequent retention of deposited particles at 2 and 24 h postdeposition was independent of L/R at the various lung volumes. Thus asymmetric bolus ventilation for these very shallow boluses does not lead to significant increases in peripheral alveolar deposition. These data may prove useful for 1) designing aerosol delivery techniques to target bronchial airways and 2) understanding airway retention of inhaled particles.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 9887127     DOI: 10.1152/jappl.1999.86.1.168

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  7 in total

Review 1.  Aerosol deposition in health and disease.

Authors:  Chantal Darquenne
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2012-06       Impact factor: 2.849

Review 2.  Particle transport and deposition: basic physics of particle kinetics.

Authors:  Akira Tsuda; Frank S Henry; James P Butler
Journal:  Compr Physiol       Date:  2013-10       Impact factor: 9.090

3.  The value of electrical impedance tomography in assessing the effect of body position and positive airway pressures on regional lung ventilation in spontaneously breathing subjects.

Authors:  Thomas Riedel; Tanya Richards; Andreas Schibler
Journal:  Intensive Care Med       Date:  2005-09-30       Impact factor: 17.440

4.  Pharmacokinetics of inhaled monodisperse beclomethasone as a function of particle size.

Authors:  J E Esposito-Festen; P Zanen; H A W M Tiddens; J-W J Lammers
Journal:  Br J Clin Pharmacol       Date:  2007-04-18       Impact factor: 4.335

5.  Regional deposition of particles in an image-based airway model: large-eddy simulation and left-right lung ventilation asymmetry.

Authors:  Andrew R Lambert; Patrick O'Shaughnessy; Merryn H Tawhai; Eric A Hoffman; Ching-Long Lin
Journal:  Aerosol Sci Technol       Date:  2011-01       Impact factor: 2.908

6.  Novel multi-functional europium-doped gadolinium oxide nanoparticle aerosols facilitate the study of deposition in the developing rat lung.

Authors:  Gautom K Das; Donald S Anderson; Chris D Wallis; Sarah A Carratt; Ian M Kennedy; Laura S Van Winkle
Journal:  Nanoscale       Date:  2016-06-02       Impact factor: 7.790

7.  Mucociliary and long-term particle clearance in airways of patients with immotile cilia.

Authors:  Winfried Möller; Karl Häussinger; Löms Ziegler-Heitbrock; Joachim Heyder
Journal:  Respir Res       Date:  2006-01-19
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.