Literature DB >> 988565

Quadrupole mass filtering for registration of blood gas partial pressures.

K W Beste, H Duchanova, G Hellige, H Prennschütz-Schützenau, H Vennebusch, H J Bretschneider.   

Abstract

With a newly developed quadrupole mass spectrometer several blood gas partial pressures are recorded simultaneously and continuously. In the mass filter the separation of the ions to be detected takes place in a hyperbolic electric field with variable direct and alternating voltages with a constant frequency of 2.4 MHz. For blood gas analysis a fully relaxed experimental animal was artifically ventilated and provided with arterial and venous catheters. Each catheter consisted flexible steel tubing (external diameter 0.6 mm) slotted near the end and covered with a silicone rubber membrane. The distance from the measuring tip to the mass spectrometer was 150 cm. Experiments with blood, in vivo equilibrated with gas mixtures, showed good reproducibility; the mean error of the helium partial pressure, for example, was less than 4%. During respiration using a gas mixture with 40% argon, the time constant t63% was found to be 55 s for the whole experimental arrangement including the experimental animal.

Entities:  

Mesh:

Substances:

Year:  1976        PMID: 988565     DOI: 10.1007/bf01067025

Source DB:  PubMed          Journal:  Pflugers Arch        ISSN: 0031-6768            Impact factor:   3.657


  18 in total

1.  Estimation of cardiac output by analysis of respiratory gas exchange.

Authors:  L D Homer; B Denysyk
Journal:  J Appl Physiol       Date:  1975-07       Impact factor: 3.531

2.  PRINCIPLES OF GAS ANALYSIS OF INTEREST TO ANESTHESIOLOGISTS.

Authors:  A WALD; V D MAZZIA
Journal:  N Y State J Med       Date:  1965-07-15

3.  [Measurement of blood-gas partial pressures in vivo with a mass spectrometer probe in a vessel with blood-flow].

Authors:  K W Beste; G Hellige; I Hensel; H D Schenk; H J Bretschneider
Journal:  Biomed Tech (Berl)       Date:  1976-04       Impact factor: 1.411

4.  Mass spectrometric determination of partial pressures of gases in liquids.

Authors:  H Löllgen; G von Nieding; H Krekeler; U Smidt
Journal:  Pneumonologie       Date:  1975-05-30

5.  The theory and applications of the exchange of inert gas at the lungs and tissues.

Authors:  S S KETY
Journal:  Pharmacol Rev       Date:  1951-03       Impact factor: 25.468

6.  The continuous measurement of pulmonary gas exchange and mechanics.

Authors:  S Z Turney; T C McAslan; R A Cowley
Journal:  Ann Thorac Surg       Date:  1972-03       Impact factor: 4.330

7.  [Diffusion processes at synthetic membranes and detection with the mass spectrometer (author's transl)].

Authors:  K W Beste
Journal:  Biomed Tech (Berl)       Date:  1974-12       Impact factor: 1.411

8.  [Measurement of organ helium perfusion through the mass spectrometric proof of heterogenous gases].

Authors:  H Becker; D Behrens; G Hellige; I Hensel; D Kettler; J Martel; H J Bretschneider
Journal:  Verh Dtsch Ges Kreislaufforsch       Date:  1973

9.  Simultaneous measurement of eight foreign gases in blood by gas chromatography.

Authors:  P D Wagner; P F Naumann; R B Laravuso
Journal:  J Appl Physiol       Date:  1974-05       Impact factor: 3.531

10.  Continuous distributions of ventilation-perfusion ratios in normal subjects breathing air and 100 per cent O2.

Authors:  P D Wagner; R B Laravuso; R R Uhl; J B West
Journal:  J Clin Invest       Date:  1974-07       Impact factor: 14.808

View more