Lecithin can be detected by volume-selected proton MR spectroscopy using a 1.5 T whole body scanner: a potentially non-invasive method for the prenatal assessment of fetal lung maturity.

B W Fenton1, C S Lin, F Seydel, C Macedonia.   

Abstract

The prenatal determination of fetal lung maturity is currently assessed by chemical analysis of surfactant associated lipids from aminotic fluid obtained by amniocentesis. This is an invasive procedure with rare but occasionally serious morbidity. Magnetic resonance spectroscopy (MRS) is a non-invasive method for the in vivo localization and identification of molecules with known resonance peaks at specified chemical shifts. In this report we examine the in vitro MRS of a lecithin/saline solution as well as term and preterm amniotic fluid samples with the use of a 1.5 T whole body scanner and a flexible surface coil. We found that amniotic fluid at term demonstrates a resonance peak at 3.2 ppm which was the same as the chemical shift of lecithin in saline. The lecithin peak is not observed in preterm amniotic fluid. This demonstrates the feasibility of using MRS with a whole body scanner to detect lecithin, one of the markers for fetal lung maturity.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9885017

Source DB:  PubMed          Journal:  Prenat Diagn        ISSN: 0197-3851            Impact factor:   3.050


  4 in total

1.  MR assessment of fetal lung development using lung volumes and signal intensities.

Authors:  Thomas M Keller; Annett Rake; Sven C A Michel; Burkhardt Seifert; Josef Wisser; Borut Marincek; Rahel A Kubik-Huch
Journal:  Eur Radiol       Date:  2004-03-11       Impact factor: 5.315

2.  Increased fetal lung T2 signal is not due to increasing surfactant concentration: an in vitro T2 mapping analysis.

Authors:  Theodore J Dubinsky; Mariam Moshiri; Kristina Adams Waldorf; Greg Wilson; Jeffrey H Maki; Daniel S Hippe
Journal:  Prenat Diagn       Date:  2017-01-25       Impact factor: 3.050

Review 3.  Exploiting mechanical stimuli to rescue growth of the hypoplastic lung.

Authors:  Edwin C Jesudason
Journal:  Pediatr Surg Int       Date:  2007-09       Impact factor: 1.827

4.  Magnetic resonance imaging of the fetal lung: a pictorial essay.

Authors:  M Cannie; J Jani; F De Keyzer; F Van Kerkhove; J Meersschaert; L Lewi; J Deprest; S Dymarkowski
Journal:  Eur Radiol       Date:  2008-02-13       Impact factor: 7.034

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.