Literature DB >> 9881390

Leucocyte filtration during cardiopulmonary bypass hardly changed leucocyte counts and did not influence myeloperoxidase, complement, cytokines or platelets.

S T Baksaas1, V Videm, T E Mollnes, S Tølløfsrud, G Hetland, T Pedersen, J L Svennevig.   

Abstract

In some patients, coronary artery bypass surgery induces postoperative organ dysfunction despite an apparently adequate revascularization and good haemodynamic performance. This complication may be caused by activation of the body's inflammatory systems on blood contact with large foreign surfaces in the extracorporeal circuit. Activated leucocytes may play an important role in organ damage, and it is conceivable that leucocyte removal by filtration may decrease the potential side-effects of cardiopulmonary bypass (CPB). The aim of the present study was to investigate possible effects of leucocyte filtration during the whole CPB period in elective coronary artery bypass surgery on biochemical and clinical parameters. Forty patients were randomized to extracorporeal circulation using a leucocyte-depleting filter (group L, n = 20) or to extracorporeal circulation with no leucocyte filter (group C, n = 20). In the leucocyte-depleted group, the mean total white blood cell counts increased from 6.3 (95% confidence interval, 5.5-7.0) x 10(9)/l to 7.0 (5.7-8.3) x 10(9)/l during extracorporeal circulation and in the control group from 6.3 (5.2-7.3) x 10(9)/l to 8.5 (7.2-9.8) x 10(9)/l. The intergroup difference was not statistically significant (p = 0.84). A substantial increase in concentrations of interleukin-6, myeloperoxidase and complement activation products were observed in both groups without statistically significant intergroup differences. It is concluded that the leucocyte-depletion filter did not cause a significant reduction of circulating white blood cells during CPB, and there were no significant differences between the groups with respect to the inflammatory markers studied.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9881390     DOI: 10.1177/026765919801300606

Source DB:  PubMed          Journal:  Perfusion        ISSN: 0267-6591            Impact factor:   1.972


  4 in total

Review 1.  From trash to leucocytes: what are we filtering and why?

Authors:  Simon J Mitchell
Journal:  J Extra Corpor Technol       Date:  2006-03

Review 2.  Use of leukocyte-depleting filters during cardiac surgery with cardiopulmonary bypass: a review.

Authors:  Shalini Boodram; Ed Evans
Journal:  J Extra Corpor Technol       Date:  2008-03

Review 3.  Lung inflammatory response syndrome after cardiac-operations and treatment of lornoxicam.

Authors:  Kosmas Tsakiridis; Andreas Mpakas; George Kesisis; Stamatis Arikas; Michael Argyriou; Stavros Siminelakis; Paul Zarogoulidis; Nikolaos Katsikogiannis; Ioanna Kougioumtzi; Theodora Tsiouda; Eirini Sarika; Ioanna Katamoutou; Konstantinos Zarogoulidis
Journal:  J Thorac Dis       Date:  2014-03       Impact factor: 2.895

4.  Long-term leukocyte filtration should be avoided during extracorporeal circulation.

Authors:  Jiali Tang; Kaiyu Tao; Jing Zhou; Chongwei Zhang; Lina Gong; Nanfu Luo; Lei Du
Journal:  Mediators Inflamm       Date:  2013-12-26       Impact factor: 4.711

  4 in total