Literature DB >> 9880639

Spiral twist of the spermatic cord: a reliable sign of testicular torsion.

C Baud1, C Veyrac, A Couture, J L Ferran.   

Abstract

BACKGROUND: Colour Doppler sonography (CDS) has become the procedure of choice in evaluating testicular perfusion but false negative findings have been reported.
OBJECTIVE: To determine if direct visualisation of the twisted spermatic cord using high resolution US is a reliable sign to assess testicular torsion.
MATERIAL AND METHODS: Thirty patients (aged 2-26 years) with equivocal diagnosis of testicular torsion prospectively underwent high resolution and CDS. The results were correlated with surgical findings. Serial transverse and longitudinal scans were performed to compare the scrotal contents on each side and study the complete spermatic cord course, from inguinal canal to testis, to detect a spiral twist.
RESULTS: In 14 of the 23 cases of torsion, the diagnosis was based on the colour Doppler findings in the scrotum because blood flow was absent in the symptomatic testis and detectable without difficulty on the normal side. In nine cases, CDS was unreliable; in six cases intratesticular perfusion was present in a twisted testis and in three small boys, no colour signal was obtained in either testis. In all cases of torsion, the spiral twist of spermatic cord was detected at the external inguinal ring. The twist induced an abrupt change in spermatic cord course, size and shape below the point of torsion. It appeared in the scrotum as a round or oval, homogeneous or heterogeneous extratesticular mass with or without blood flow, that could be connected cephalad with the normal inguinal cord. In the other seven cases (three late torsions of the appendix testis, one epididymo-orchitis and three torsions with spontaneous reduction), no spiral twist was detectable.
CONCLUSION: The detection of spermatic cord spiral twist appears a reliable US sign of torsion whatever the testicular consequences.

Entities:  

Mesh:

Year:  1998        PMID: 9880639     DOI: 10.1007/s002470050507

Source DB:  PubMed          Journal:  Pediatr Radiol        ISSN: 0301-0449


  14 in total

1.  MRI in the diagnosis of incomplete testicular torsion.

Authors:  G T Gotto; S D Chang; Mark K Nigro
Journal:  Br J Radiol       Date:  2010-05       Impact factor: 3.039

2.  The "whirlpool sign", a US finding in partial torsion of the spermatic cord: 4 cases.

Authors:  Francesco Esposito; Marco Di Serafino; Carmela Mercogliano; Valerio Vitale; Paolo Sgambati; Gianfranco Vallone
Journal:  J Ultrasound       Date:  2014-07-03

3.  The ultrasonographic "whirlpool sign" in testicular torsion: valuable tool or waste of valuable time? A systematic review and meta-analysis.

Authors:  Jared McDowall; Ahmed Adam; Louis Gerber; Callistus O A Enyuma; Sunday J Aigbodion; Sean Buchanan; Abdullah E Laher
Journal:  Emerg Radiol       Date:  2018-01-15

4.  Sonographic appearances of the epididymis in boys with acute testicular torsion but preserved testicular blood flow on color Doppler.

Authors:  Paraskevi Galina; Vasiliki Dermentzoglou; Nikolaos Baltogiannis; Maria Zarifi
Journal:  Pediatr Radiol       Date:  2015-06-24

5.  Clinical and sonographic criteria of acute scrotum in children: a retrospective study of 172 boys.

Authors:  Boaz Karmazyn; Ran Steinberg; Liora Kornreich; Enrique Freud; Sylvia Grozovski; Michael Schwarz; Nitza Ziv; Pinchas Livne
Journal:  Pediatr Radiol       Date:  2004-10-16

6.  Torsion of a seminoma in an intrascrotal testis: A case report and review of the literature.

Authors:  Tatsuo Gondo; Kazunori Namiki; Ayako Tanaka; Kunihiko Yoshioka; Michio Tanaka; Hidenobu Yamamoto; Masaaki Tachibana
Journal:  Can Urol Assoc J       Date:  2013 Jan-Feb       Impact factor: 1.862

7.  US in the assessment of acute scrotum.

Authors:  Alfredo D'Andrea; Francesco Coppolino; Elviro Cesarano; Anna Russo; Salvatore Cappabianca; Eugenio Annibale Genovese; Paolo Fonio; Luca Macarini
Journal:  Crit Ultrasound J       Date:  2013-07-15

8.  Intermittent Testicular Torsion in Adults: An Overlooked Clinical Condition.

Authors:  Ahmed M Al-Kandari; Elijah O Kehinde; Salah Khudair; Hamdy Ibrahim; Mohammed S ElSheemy; Ahmed A Shokeir
Journal:  Med Princ Pract       Date:  2016-09-19       Impact factor: 1.927

Review 9.  Ultrasonography of pediatric urogenital emergencies: review of classic and new techniques.

Authors:  Masahiro Kitami
Journal:  Ultrasonography       Date:  2017-03-30

10.  Neonatal testicular torsion; a review article.

Authors:  Muhammad Riaz-Ul-Haq; Diaa Eldin Abdelhamid Mahdi; Elbagir Uthman Elhassan
Journal:  Iran J Pediatr       Date:  2012-09       Impact factor: 0.364