Literature DB >> 9879360

A universal algorithm for fast and automated charge state deconvolution of electrospray mass-to-charge ratio spectra.

Z Zhang1, A G Marshall.   

Abstract

This article describes a new algorithm for charge state determination and deconvolution of electrospray ionization (ESI) mass-to-charge ratio spectra. The algorithm (ZSCORE) is based on a charge scoring scheme that incorporates all above-threshold members of a family of charge states or isotopic components, and deconvolves both low- and high-resolution mass-to-charge ratio spectra, with or without a peak list (stick plot). A scoring weight factor, log (I/I0), in which I is the signal magnitude at a calculated mass-to-charge ratio, and I0 is the signal threshold near that mass-to-charge ratio, was used in most cases. For high-resolution mass-to-charge ratio spectra in which all isotopic peaks are resolved, the algorithm can deconvolve overlapped isotopic multiplets of the same or different charge state. Compared to other deconvolution techniques, the algorithm is robust, rapid, and fully automated (i.e., no user input during the deconvolution process). It eliminates artifact peaks without introducing peak distortions. Its performance is demonstrated for experimental ESI Fourier transform ion cyclotron resonance mass-to-charge ratio spectra (both low and high resolution). Charge state deconvolution to yield a "zero-charge" mass spectrum should prove particularly useful for interpreting spectra of complex mixtures, identifying contaminants, noncovalent adducts, fragments (N-terminal, C-terminal, internal), and chemical modifications of electrosprayed biomacromolecules.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9879360     DOI: 10.1016/S1044-0305(97)00284-5

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  7 in total

1.  Electrospray ionization mass spectrometry: Deconvolution by an Entropy-Based algorithm.

Authors:  B B Reinhold; V N Reinhold
Journal:  J Am Soc Mass Spectrom       Date:  1992-03       Impact factor: 3.109

2.  Automated assignment of charge states from resolved isotopic peaks for multiply charged ions.

Authors:  M W Senko; S C Beu; F W McLafferty
Journal:  J Am Soc Mass Spectrom       Date:  1995-01       Impact factor: 3.109

3.  Characterization of cytochrome c variants with high-resolution FTICR mass spectrometry: correlation of fragmentation and structure.

Authors:  Q Wu; S Van Orden; X Cheng; R Bakhtiar; R D Smith
Journal:  Anal Chem       Date:  1995-07-15       Impact factor: 6.986

4.  A high-performance modular data system for Fourier transform ion cyclotron resonance mass spectrometry.

Authors:  M W Senko; J D Canterbury; S Guan; A G Marshall
Journal:  Rapid Commun Mass Spectrom       Date:  1996       Impact factor: 2.419

5.  Electrospray ionization Fourier transform ion cyclotron resonance at 9.4 T.

Authors:  M W Senko; C L Hendrickson; L Pasa-Tolić; J A Marto; F M White; S Guan; A G Marshall
Journal:  Rapid Commun Mass Spectrom       Date:  1996       Impact factor: 2.419

6.  The determination of protein, oligonucleotide and peptide molecular weights by ion-spray mass spectrometry.

Authors:  T R Covey; R F Bonner; B I Shushan; J Henion
Journal:  Rapid Commun Mass Spectrom       Date:  1988-11       Impact factor: 2.419

Review 7.  Electrospray ionization for mass spectrometry of large biomolecules.

Authors:  J B Fenn; M Mann; C K Meng; S F Wong; C M Whitehouse
Journal:  Science       Date:  1989-10-06       Impact factor: 47.728

  7 in total
  177 in total

1.  Automated reduction and interpretation of high resolution electrospray mass spectra of large molecules.

Authors:  D M Horn; R A Zubarev; F W McLafferty
Journal:  J Am Soc Mass Spectrom       Date:  2000-04       Impact factor: 3.109

2.  MoWeD, a computer program to rapidly deconvolute low resolution electrospray liquid chromatography/mass spectrometry runs to determine component molecular weights.

Authors:  J O Pearcy; T D Lee
Journal:  J Am Soc Mass Spectrom       Date:  2001-05       Impact factor: 3.109

3.  Retention time alignment of LC/MS data by a divide-and-conquer algorithm.

Authors:  Zhongqi Zhang
Journal:  J Am Soc Mass Spectrom       Date:  2012-04       Impact factor: 3.109

4.  Dynamics of a bacterial multidrug ABC transporter in the inward- and outward-facing conformations.

Authors:  Shahid Mehmood; Carmen Domene; Eric Forest; Jean-Michel Jault
Journal:  Proc Natl Acad Sci U S A       Date:  2012-06-18       Impact factor: 11.205

5.  Conformational dynamics of the bovine mitochondrial ADP/ATP carrier isoform 1 revealed by hydrogen/deuterium exchange coupled to mass spectrometry.

Authors:  Martial Rey; Petr Man; Benjamin Clémençon; Véronique Trézéguet; Gérard Brandolin; Eric Forest; Ludovic Pelosi
Journal:  J Biol Chem       Date:  2010-08-30       Impact factor: 5.157

6.  Deconvolution and database search of complex tandem mass spectra of intact proteins: a combinatorial approach.

Authors:  Xiaowen Liu; Yuval Inbar; Pieter C Dorrestein; Colin Wynne; Nathan Edwards; Puneet Souda; Julian P Whitelegge; Vineet Bafna; Pavel A Pevzner
Journal:  Mol Cell Proteomics       Date:  2010-09-20       Impact factor: 5.911

7.  Low temperature dynamic mapping reveals unexpected order and disorder in troponin.

Authors:  Devanand Kowlessur; Larry S Tobacman
Journal:  J Biol Chem       Date:  2010-10-02       Impact factor: 5.157

8.  The surprising composition of the salivary proteome of preterm human newborn.

Authors:  Massimo Castagnola; Rosanna Inzitari; Chiara Fanali; Federica Iavarone; Alberto Vitali; Claudia Desiderio; Giovanni Vento; Chiara Tirone; Costantino Romagnoli; Tiziana Cabras; Barbara Manconi; Maria Teresa Sanna; Roberto Boi; Elisabetta Pisano; Alessandra Olianas; Mariagiuseppina Pellegrini; Sonia Nemolato; Claus Wilhelm Heizmann; Gavino Faa; Irene Messana
Journal:  Mol Cell Proteomics       Date:  2010-10-13       Impact factor: 5.911

9.  Molecular insight into the conformational dynamics of the Elongin BC complex and its interaction with HIV-1 Vif.

Authors:  Sean R Marcsisin; John R Engen
Journal:  J Mol Biol       Date:  2010-08-20       Impact factor: 5.469

10.  Hydrogen/deuterium exchange mass spectrometry and site-directed disulfide cross-linking suggest an important dynamic interface between the two lysostaphin domains.

Authors:  Hai-Rong Lu; Mei-Gang Gu; Qiang Huang; Jin-jiang Huang; Wan-Ying Lu; Hong Lu; Qing-Shan Huang
Journal:  Antimicrob Agents Chemother       Date:  2013-02-04       Impact factor: 5.191

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.