Literature DB >> 9877396

In vitro strength comparison of hydroxyapatite cement and polymethylmethacrylate in subchondral defects in caprine femora.

K Crawford1, B H Berrey, W A Pierce, R D Welch.   

Abstract

Hydroxyapatite cement was investigated in situ for the reconstruction of juxta-articular defects. Polymethylmethacrylate is currently the most commonly used material for the reconstruction of bone defects following the exteriorization and curettage of aggressive benign tumors. In vitro, we compared the effects of hydroxyapatite cement and polymethylmethacrylate in restoring the stiffness of the subchondral plate in a caprine femoral defect model. Ten matched pairs of caprine femora underwent nondestructive compression testing normal to the load-bearing surface. A standardized subchondral defect 12 mm in diameter was created in the medial femoral condyle. Compression testing was repeated to determine the reduction in stiffness caused by the defect. Each femur from each pair was randomly assigned to one of two groups (n=9), and the defects were augmented with either polymethylmethacrylate or hydroxyapatite cement. After 12 hours, compression testing was repeated to determine the subchondral stiffness after augmentation. Compared with intact femora, the defect specimens that were later treated with either polymethylmethacrylate or hydroxyapatite cement exhibited stiffness values of 70 (386+/-107 N/mm) and 59% (343+/-94 N/mm) respectively, which represented a significant reduction in stiffness (p=0.05). Augmentation with polymethylmethacrylate or hydroxyapatite cement restored stiffness by 81 (450+/-111 N/mm) and 71% (413+/-115 N/mm), respectively, of the values of intact specimens. Hydroxyapatite cement restored stiffness significantly (p=0.05) over the stiffness of the nonaugmented defect compared with the stiffness after augmentation with polymethylmethacrylate (p=0.12). Neither polymethylmethacrylate nor hydroxyapatite cement restored stiffness to that of intact femora (p=0.05). In the current detect model, hydroxyapatite cement was comparable with polymethylmethacrylate in restoring subchondral stiffness. Unlike polymethylmethacrylate, however, hydroxyapatite cement has the following advantages: it is osteoconductive, is replaced by host bone, and avoids the potential for thermal necrosis. Hydroxyapatite cement may therefore provide a viable alternative to polymethylmethacrylate for augmentation of juxta-articular and other bone defects.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9877396     DOI: 10.1002/jor.1100160613

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  3 in total

1.  Supplemental Bone Grafting in Giant Cell Tumor of the Extremity Reduces Nononcologic Complications.

Authors:  Joseph Benevenia; Steven M Rivero; Jeffrey Moore; Joseph A Ippolito; Daniel A Siegerman; Kathleen S Beebe; Francis R Patterson
Journal:  Clin Orthop Relat Res       Date:  2017-03       Impact factor: 4.176

2.  A novel subchondral bone-grafting procedure for the treatment of giant-cell tumor around the knee: A retrospective study of 27 cases.

Authors:  Minhao Wu; Shiyi Yao; Yuanlong Xie; Feifei Yan; Zhouming Deng; Jun Lei; Lin Cai
Journal:  Medicine (Baltimore)       Date:  2018-11       Impact factor: 1.889

Review 3.  Antimicrobial surfaces for craniofacial implants: state of the art.

Authors:  Lisa Actis; Laura Gaviria; Teja Guda; Joo L Ong
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2013-04-23
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.