Literature DB >> 9877216

A time-resolved fluoroimmunoassay for cortisol in unextracted bovine plasma or serum with optimized procedures to eliminate steroid binding protein interference and to minimize non-specific streptavidin-europium binding.

J H Erkens1, S J Dieleman, R A Dressendörfer, C J Strasburger.   

Abstract

A time-resolved fluoroimmunoassay (TR-FIA) for human salivary cortisol was adapted for the measurement of cortisol in unextracted bovine blood plasma and serum. It has been demonstrated that the binding of cortisol binding plasma proteins (CBPP) to the cortisol-biotin primary probe cannot be eliminated by means of cortisol releasing agents. Complete inactivation of CBPP was achieved by heating water diluted samples for 30 min at 80 degrees C. The high non-specific binding (NSB) of the streptavidin-europium secondary probe, encountered during preliminary experiments, was shown to be caused by an interaction with bovine serum albumin (BSA) and could be reduced partly by the addition of heparin. It was also shown that the ability to bind streptavidin-europium nonspecifically is not a general property of proteins since bovine gamma-globulin and gelatin lack this behaviour. The advantage of a highly reduced NSB, resulting from the use of a BSA free assay buffer, is not limited to this particular assay but is also beneficial for other procedures based on specific measurement of streptavidin-europium fluorescence. The detection limit for a 20 microl sample was 0.5 ng/ml. The intra-assay coefficients of variation for control samples with cortisol concentrations of 71.1, 39.2 and 10.3 ng/ml were 8.2, 7.9 and 11.3% (n = 16). The corresponding inter-assay coefficients of variation were 7.3, 9.0 and 11.2% (n = 73). Correlation with a commercially available radioimmunoassay, preceded by diethylether extraction of the sample, was 0.97 (n = 88).

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9877216     DOI: 10.1016/s0960-0760(98)00083-1

Source DB:  PubMed          Journal:  J Steroid Biochem Mol Biol        ISSN: 0960-0760            Impact factor:   4.292


  4 in total

1.  Cortisol and free thyroxine determination by time-resolved fluorometry in canine serum.

Authors:  M D Parra; L J Bernal; J J Cerón
Journal:  Can J Vet Res       Date:  2004-04       Impact factor: 1.310

2.  Dual-label time-resolved fluoroimmunoassay for simultaneous quantification of haptoglobin and C-reactive protein in meat juice from pigs.

Authors:  Ana M Gutiérrez; José J Cerón; Blas A Marsilla; María D Parra; Silvia Martinez-Subiela
Journal:  Can J Vet Res       Date:  2012-04       Impact factor: 1.310

3.  Tinnitus and hyperacusis: Contributions of paraflocculus, reticular formation and stress.

Authors:  Yu-Chen Chen; Guang-Di Chen; Benjamin D Auerbach; Senthilvelan Manohar; Kelly Radziwon; Richard Salvi
Journal:  Hear Res       Date:  2017-03-07       Impact factor: 3.208

4.  Analytical and clinical validation of a time-resolved immunofluorometric assay (TR-IFMA) for canine C-reactive protein in serum.

Authors:  M D Parra; M Tuomola; J Cabezas-Herrera; J J Cerón
Journal:  Vet Res Commun       Date:  2006-02       Impact factor: 2.459

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.