Literature DB >> 9874818

Anisotropy functions for 125I and 103Pd sources.

K Weaver1.   

Abstract

The anisotropy function was defined by AAPM Task Group 43 in a recent report, and reference data were provided. However, some of the data appeared to have large experimental errors. In this work, anisotropy functions are presented for three low-energy photon-emitting sources commonly used for brachytherapy: 125I source models 6702 and 6711, and the model 200 103Pd source. The data were generated via a two-step process: the sources' intrinsic radiation emission pattern was determined from in-air measurements, and these data were used as input to Monte Carlo calculations of the fluence distribution in water. The new anisotropy function values for iodine compare well with earlier data from diode measurements, and seem more physically realistic than some data provided by TG43. Previous palladium data measured with TLDs are more variable, but on the average are similar to the data presented here. The new data have estimated uncertainties of 3%-6%; this level of accuracy should be completely adequate for clinical calculations.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9874818     DOI: 10.1118/1.598458

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  An analytical model to determine interseed attenuation effect in low-dose-rate brachytherapy.

Authors:  Habib Safigholi; Dariush Sardari; Somaye Karimi Jashni; Seied Rabi Mahdavi; Ali S Meigooni
Journal:  J Appl Clin Med Phys       Date:  2013-05-06       Impact factor: 2.102

2.  Dosimetric parameters of three new solid core I-125 brachytherapy sources.

Authors:  Timothy D Solberg; John J DeMarco; Geoffrey Hugo; Robert E Wallace
Journal:  J Appl Clin Med Phys       Date:  2002       Impact factor: 2.102

3.  Determination of dosimetric parameters for shielded 153Gd source in prostate cancer brachytherapy.

Authors:  Mahdi Ghorbani; Benyamin Khajetash; Najmeh Ghatei; Mohammad Mehrpouyan; Ali S Meigooni; Ramin Shahraini
Journal:  Radiol Oncol       Date:  2017-02-22       Impact factor: 2.991

4.  Experimental iodine-125 seed irradiation of intracerebral brain tumors in nude mice.

Authors:  Joost J C Verhoeff; Lukas J A Stalpers; Annet W Coumou; Kees Koedooder; Cristina Lavini; Cornelis J F Van Noorden; Jaap Haveman; William P Vandertop; Wouter R van Furth
Journal:  Radiat Oncol       Date:  2007-09-26       Impact factor: 3.481

5.  Monte Carlo dosimetric characterization of the IsoAid ADVANTAGE 103Pd brachytherapy source.

Authors:  Keith T Sowards
Journal:  J Appl Clin Med Phys       Date:  2007-03-20       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.