Literature DB >> 9872553

Occlusion of the abdominal aorta caused by enlargement of the false lumen after graft replacement for a DeBakey type IIIb dissecting aneurysm: report of a case.

T Koshino1, T Kazui, Y Tamiya, J Fukada, R Koushima, K Morishita, T Abe.   

Abstract

We report herein a case of abdominal aorta occlusion caused by enlargement of the false lumen after a graft replacement. The patient was a 70-year-old man who underwent a graft replacement of the descending thoracic aorta for a DeBakey type IIIb dissecting aneurysm. Digital subtraction angiography performed on postoperative day 18 revealed an abdominal aorta occlusion caused by enlargement of the false lumen. A new intimal defect was found in the aortic wall 2 cm distal to the suture line, the cause of which was suspected to be clamp injury during the initial operation. Graft replacement of the abdominal aorta was subsequently carried out. Postoperatively, he had no complications, and digital subtraction angiography showed excellent reconstruction of the abdominal aorta. The patient was discharged from hospital 1 month after his second operation.

Entities:  

Mesh:

Year:  1998        PMID: 9872553     DOI: 10.1007/BF02482819

Source DB:  PubMed          Journal:  Surg Today        ISSN: 0941-1291            Impact factor:   2.549


  7 in total

1.  [Consideration of management of type B dissecting aneurysms of the thoracic aorta: clinical comparative study between surgical and medical treatments].

Authors:  T Kazui; N Inoue; T Yamaguchi; O Yamada; S Komatsu; Y Asai; T Shoji; M Kaneko
Journal:  Kyobu Geka       Date:  1990-11

2.  Atheroembolism from the ascending aorta. An emerging problem in cardiac surgery.

Authors:  C I Blauth; D M Cosgrove; B W Webb; N B Ratliff; M Boylan; M R Piedmonte; B W Lytle; F D Loop
Journal:  J Thorac Cardiovasc Surg       Date:  1992-06       Impact factor: 5.209

3.  [Injury to ascending aorta by cross-clamp--histologic evaluation].

Authors:  T Takano; Y Fukaya; H Tsunemoto; H Nakano; H Kuroda; J Amano; H Hikita; S Kouzu; H Nobara
Journal:  Nihon Kyobu Geka Gakkai Zasshi       Date:  1996-12

4.  Four-year clinical experience with the gelatin-resorcine-formol biological glue in acute aortic dissection.

Authors:  J Bachet; F Gigou; C Laurian; O Bical; B Goudot; D Guilmet
Journal:  J Thorac Cardiovasc Surg       Date:  1982-02       Impact factor: 5.209

5.  Acute dissecting aneurysms of the aorta: diagnosis and treatment--1979.

Authors:  M W Wheat
Journal:  Am Heart J       Date:  1980-03       Impact factor: 4.749

6.  Intraoperative aortic dissection.

Authors:  R J Still; A D Hilgenberg; C W Akins; W M Daggett; M J Buckley
Journal:  Ann Thorac Surg       Date:  1992-03       Impact factor: 4.330

7.  [A repair of the aortic pseudoaneurysm after ascending aortic grafting in acute type A dissection--a case report].

Authors:  I Fukuda; H Ohuchi; K Matsuzaki
Journal:  Nihon Kyobu Geka Gakkai Zasshi       Date:  1995-04
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.