Effects of radiofrequency catheter ablation on patients with permanent pacemakers.

N Sadoul1, I Blankoff, C de Chillou, D Beurrier, M Messier, O Bizeau, I Magnin, B Dodinot, E Aliot.   

Abstract

The objective of this study was to assess the effects of radiofrequency energy application on implanted pacemaker functions. Radiofrequency (RF) catheter ablation may cause pacemaker dysfunction due to electromagnetic interferences. The effects of RF on pacemaker behavior were studied in a series of 38 pacemakers, implanted 18 +/- 26 months prior to a RF procedure using either a right ventricular approach (AV node ablation, n = 35) or a left ventricular approach (left concealed accessory pathway ablation, n = 1; VT ablation, n = 2). The 38 patients (mean age 65 +/- 9 years) included 20 men and 18 women. Before energy applications, the 23 different pacemaker models were programmed to the VVI mode at the lowest available rate. The continuous surface ECG was recorded throughout the procedure. Thorough testing of the devices was performed before and after each RF delivery. Unusual pacemaker responses occurred in 20 of the 38 cases studied (53%). The impact of RF delivery was unpredictable, and variable dysfunctions were observed at different times for a given patient or could vary for a given model. Unusual pacemaker responses included pacemaker inhibition (n = 8), untoggled backup mode (n = 3), electromagnetic interference noise mode (n = 3), temporary RF-induced pacemaker tachycardia (n = 2), erratic behavior (n = 1), oversensing of RF onset and offset (n = 8), and transient loss of ventricular capture, (n = 1). Postablation, most devices automatically toggled back to full functionality. The three devices in the untoggled backup mode had to be reprogrammed to obtain normal operations. At the end of the procedure, pacing thresholds remained unchanged in all but one patient, in whom the increase in ventricular threshold was due to a nicked lead. In conclusion, implanted pacemakers frequently exhibit transient, unpredictable responses to RF energy application. Although all pacemaker functions were restored postablation, some devices had to be reset manually. The anomalies observed during the RF application argue for the simultaneous use of an external pacemaker in pacing-dependent patients.

Entities:  

Mesh:

Year:  1997        PMID: 9869976     DOI: 10.1023/a:1009721023732

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  11 in total

1.  Catheter ablation of accessory atrioventricular pathways (Wolff-Parkinson-White syndrome) by radiofrequency current.

Authors:  W M Jackman; X Z Wang; K J Friday; C A Roman; K P Moulton; K J Beckman; J H McClelland; N Twidale; H A Hazlitt; M I Prior
Journal:  N Engl J Med       Date:  1991-06-06       Impact factor: 91.245

2.  The effect of radiofrequency catheter ablation on permanent pacemakers: an experimental study.

Authors:  M C Chin; M Rosenqvist; M A Lee; J C Griffin; J J Langberg
Journal:  Pacing Clin Electrophysiol       Date:  1990-01       Impact factor: 1.976

3.  The influence of elevated 50 Hz electric and magnetic fields on implanted cardiac pacemakers: the role of the lead configuration and programming of the sensitivity.

Authors:  L Toivonen; J Valjus; M Hongisto; R Metso
Journal:  Pacing Clin Electrophysiol       Date:  1991-12       Impact factor: 1.976

4.  Radiofrequency catheter ablation of ventricular tachycardia in patients without structural heart disease.

Authors:  L S Klein; H T Shih; F K Hackett; D P Zipes; W M Miles
Journal:  Circulation       Date:  1992-05       Impact factor: 29.690

5.  Acute effects of radiofrequency ablation of atrial arrhythmias on implanted permanent pacing systems.

Authors:  K A Ellenbogen; M A Wood; B S Stambler
Journal:  Pacing Clin Electrophysiol       Date:  1996-09       Impact factor: 1.976

6.  Pacemaker function during radiofrequency ablation.

Authors:  D Pfeiffer; J Tebbenjohanns; B Schumacher; W Jung; B Lüderitz
Journal:  Pacing Clin Electrophysiol       Date:  1995-05       Impact factor: 1.976

7.  Catheter ablation of the atrioventricular junction with radiofrequency energy.

Authors:  J J Langberg; M C Chin; M Rosenqvist; J Cockrell; N Dullet; G Van Hare; J C Griffin; M M Scheinman
Journal:  Circulation       Date:  1989-12       Impact factor: 29.690

8.  Testing of work environments for electromagnetic interference.

Authors:  D Marco; G Eisinger; D L Hayes
Journal:  Pacing Clin Electrophysiol       Date:  1992-11       Impact factor: 1.976

9.  Radiofrequency catheter ablation of atrial arrhythmias. Results and mechanisms.

Authors:  M D Lesh; G F Van Hare; L M Epstein; A P Fitzpatrick; M M Scheinman; R J Lee; M A Kwasman; H R Grogin; J C Griffin
Journal:  Circulation       Date:  1994-03       Impact factor: 29.690

10.  Radiofrequency catheter atrioventricular node ablation in patients with permanent cardiac pacing systems.

Authors:  A C Chang; D McAreavey; D Tripodi; L Fananapazir
Journal:  Pacing Clin Electrophysiol       Date:  1994-01       Impact factor: 1.976

View more
  10 in total

Review 1.  [Perioperative management of patients with implanted pacemakers or cardioverter/defibrillators. Recommendations of the Austrian Society for Anaesthesiology, Resuscitation and Intensive Care Medicine, the Austrian Society for Cardiology and the Austrian Society for Surgery].

Authors:  H Gombotz; M Anelli Monti; N Leitgeb; M Nürnberg; B Strohmer
Journal:  Anaesthesist       Date:  2009-05       Impact factor: 1.041

Review 2.  Rate Control in Atrial Fibrillation: Avoiding Morbidity.

Authors:  Thomas D Callahan
Journal:  J Atr Fibrillation       Date:  2012-12-16

3.  Effects of external electrical and magnetic fields on pacemakers and defibrillators: from engineering principles to clinical practice.

Authors:  Roy Beinart; Saman Nazarian
Journal:  Circulation       Date:  2013-12-24       Impact factor: 29.690

Review 4.  A review on atrioventricular junction ablation and pacing for heart rate control of atrial fibrillation.

Authors:  Konstantinos Vlachos; Konstantinos P Letsas; Panagiotis Korantzopoulos; Tong Liu; Michael Efremidis; Antonios Sideris
Journal:  J Geriatr Cardiol       Date:  2015-09       Impact factor: 3.327

5.  Twitching of the Pacemaker Pocket Induced by Radiofrequency Energy Delivery to the Cavotricuspid Isthmus.

Authors:  Taku Omori; Eitaro Fujii; Yoshihiko Kagawa; Satoshi Fujita; Tetsuya Kitamura; Masaaki Ito
Journal:  Intern Med       Date:  2017-12-21       Impact factor: 1.271

Review 6.  The Effects of Catheter Ablation on Permanent Pacemakers and Implantable Cardiac Defibrillators.

Authors:  Yousef H Darrat; Gustavo X Morales; Claude S Elayi
Journal:  J Innov Card Rhythm Manag       Date:  2017-03-15

Review 7.  Perioperative Management of Patients with Cardiac Implantable Electronic Devices and Utility of Magnet Application.

Authors:  Tardu Özkartal; Andrea Demarchi; Maria Luce Caputo; Enrico Baldi; Giulio Conte; Angelo Auricchio
Journal:  J Clin Med       Date:  2022-01-28       Impact factor: 4.241

8.  Cardiac Implantable Electronic Devices and Consumer Electronic Devices: The Proof Is in the Front Pocket.

Authors:  Christopher R Ellis; Nicholas E King
Journal:  J Innov Card Rhythm Manag       Date:  2022-07-15

9.  Epicardial Unipolar Lead Loss of Ventricular Capture during Radiofrequency Ablation of Atrial Fibrillation.

Authors:  Daniel J Chu; Wilson W Lam
Journal:  Case Rep Cardiol       Date:  2020-01-20

10.  Neuromuscular electrical stimulation for a dysphagic stroke patient with cardiac pacemaker using magnet mode change: A case report.

Authors:  Myeongkyu Kim; Jin-Kyu Park; Ji Young Lee; Mi Jung Kim
Journal:  World J Clin Cases       Date:  2021-07-06       Impact factor: 1.337

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.