Literature DB >> 9869771

Ventriculoarterial coupling with intra-aortic balloon pump in acute ischemic heart failure.

O Kawaguchi1, W E Pae, B B Daily, W S Pierce.   

Abstract

PURPOSE: We analyzed the mechanism of effects of intra-aortic balloon pumping using the pressure-volume relationship and ventriculoarterial coupling in the normal and failing hearts. MATERIALS: In 12 anesthetized Holstein calves (weight, 94 +/- 8 kg), the ventricular end-systolic and arterial elastances, pressure-volume area, and external work were analyzed during steady-state contractions with traditional hemodynamic parameters with intra-aortic balloon pumping-off and -on (1:1 synchronous ratio). An acute ischemic heart failure was induced by injecting 10 microm microspheres (4.2 +/- 1.8 x 10(7). 100g left ventricular weight-1) into the left main coronary artery; all measurements were repeated.
RESULTS: Intra-aortic balloon pumping did not change hemodynamic parameters in the control. However, during heart failure, intra-aortic balloon pumping decreased the arterial elastance from 3.6 +/- 1.3 mm Hg to 2.9 +/- 1.2 mm Hg. mL-1 while not affecting the ventricular end-systolic elastance, this resulted in an improvement of the ventriculoarterial coupling ratio from 3.1 +/- 0.8 to 2.3 +/- 0.8. Intra-aortic balloon pumping decreased not only end-systolic pressure (from 69 +/- 16 mm Hg to 64 +/- 19 mm Hg) but end-diastolic volume and pressure (from 139 +/- 38 mL to 137 +/- 37 mL and from 13. 9 mm Hg to 12.8 mm Hg, respectively) with the leftward shift of the pressure-volume loop. Pressure-volume area decreased (from 914 +/- 284 mm Hg to 849 +/- 278 mm Hg. mL) although stroke volume increased (from 21 +/- 6 mL to 24 +/- 6 mL).
CONCLUSION: Reduction of the arterial elastance with intra-aortic balloon pumping improved the ventriculoarterial coupling ratio and increased stroke volume. Leftward shift of the pressure-volume loop resulted in the reduction of pressure-volume area, which suggests the conservation of the myocardial oxygen consumption.

Entities:  

Mesh:

Year:  1999        PMID: 9869771     DOI: 10.1016/s0022-5223(99)70482-4

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  6 in total

1.  Intra-aortic balloon pumping reduces the increased arterial load caused by acute cardiac depression, modifying central and peripheral load determinants in a time- and flow-related way.

Authors:  Daniel Bia; Edmundo I Cabrera-Fischer; Yanina Zócalo; Ricardo L Armentano
Journal:  Heart Vessels       Date:  2011-11-09       Impact factor: 2.037

2.  Hemodynamic differences between the awake and anesthetized conditions in normal calves.

Authors:  Tohru Takaseya; Masako Fujiki; Akira Shiose; Hyun-Il Kim; Mariko Kobayashi; Alex L Massiello; Raymond Dessoffy; Sharif Al-Ruzzeh; Kiyotaka Fukamachi
Journal:  J Artif Organs       Date:  2012-03-24       Impact factor: 1.731

3.  Effects of intra-aortic balloon pump counterpulsation on left ventricular mechanoenergetics in a porcine model of acute ischemic heart failure.

Authors:  Konstantinos Malliaras; Efstratios Charitos; Nikolaos Diakos; Iraklis Pozios; Apostolos Papalois; John Terrovitis; John Nanas
Journal:  J Cardiovasc Transl Res       Date:  2014-11-07       Impact factor: 4.132

4.  Intra-aortic Balloon Counterpulsation for High-Risk Percutaneous Coronary Intervention: Defining Coronary Responders.

Authors:  Natalia Briceno; Kalpa De Silva; Matthew Ryan; Tiffany Patterson; Kevin O'Gallagher; Howard Ellis; Simone Rivolo; Jack Lee; Simon Redwood; Ajay M Shah; Michael Marber; Divaka Perera
Journal:  J Cardiovasc Transl Res       Date:  2019-03-15       Impact factor: 4.132

5.  Determination of cardiac output from pulse pressure contour during intra-aortic balloon pumping in patients with low ejection fraction.

Authors:  Jos R C Jansen; Marcelo B Bastos; Pat Hanlon; Nicolas M Van Mieghem; Ottavio Alfieri; Jan J Schreuder
Journal:  J Clin Monit Comput       Date:  2019-05-14       Impact factor: 2.502

6.  Intraoperative intra-aortic balloon pump improves 30-day outcomes of patients undergoing extensive coronary endarterectomy.

Authors:  Zhen Wu; Changcheng Liu; Ying Fang; Hua Wei; Chengxiong Gu
Journal:  J Cardiothorac Surg       Date:  2020-08-20       Impact factor: 1.637

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.