Literature DB >> 9868918

On-line MALDI-TOF MS using a continuous vacuum deposition interface.

J Preisler1, F Foret, B L Karger.   

Abstract

In this work, a new interface for continuous on-line MALDI-TOF MS is presented. The sample, mixed with a suitable matrix, was transported into the evacuated source chamber of the mass spectrometer at liquid flow rates of 100-400 nL/min. The liquid sample matrix was deposited on a rotating quartz wheel and transported to the repeller, where laser desorption took place. Rapid evaporation of the solvent (water or methanol) on the surface of the wheel resulted in formation of a thin, approximately 50-micron-wide, sample trace. Scanning electron microscopic photographs of the vacuum-dried trace revealed the deposited material to consist of an amorphous film. Furthermore, sample uniformity along the trace, in conjunction with its narrow width, resulted in excellent signal reproducibility, with detection limits in the attomole range. The interface permitted the on-line coupling of microcolumn separation techniques with MALDI MS, as demonstrated in the capillary electrophoresis MALDI-TOF MS analysis of a 12-peptide mixture. The approach offers the potential for rapid separation and trace analysis of complex mixtures.

Entities:  

Mesh:

Year:  1998        PMID: 9868918     DOI: 10.1021/ac9807823

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  8 in total

1.  An exponential dilution gradient system for nanoscale liquid chromatography in combination with MALDI or nano-ESI mass spectrometry for proteolytic digests.

Authors:  C E Doneanu; D A Griffin; E L Barofsky; D F Barofsky
Journal:  J Am Soc Mass Spectrom       Date:  2001-11       Impact factor: 3.109

2.  On-line single droplet deposition for MALDI mass spectrometry.

Authors:  Xia Zhang; Damien A Narcisse; Kermit K Murray
Journal:  J Am Soc Mass Spectrom       Date:  2004-10       Impact factor: 3.109

Review 3.  Proteome research based on modern liquid chromatography--tandem mass spectrometry: separation, identification and quantification.

Authors:  T Fröhlich; G J Arnold
Journal:  J Neural Transm (Vienna)       Date:  2006-07-13       Impact factor: 3.575

4.  Comparison between vacuum sublimed matrices and conventional dried droplet preparation in MALDI-TOF mass spectrometry.

Authors:  Thorsten W Jaskolla; Michael Karas; Udo Roth; Kerstin Steinert; Christoph Menzel; Karsten Reihs
Journal:  J Am Soc Mass Spectrom       Date:  2009-02-12       Impact factor: 3.109

5.  Development of an automated digestion and droplet deposition microfluidic chip for MALDI-TOF MS.

Authors:  Jeonghoon Lee; Harrison K Musyimi; Steven A Soper; Kermit K Murray
Journal:  J Am Soc Mass Spectrom       Date:  2008-04-08       Impact factor: 3.109

6.  Western blotting using capillary electrophoresis.

Authors:  Gwendolyn J Anderson; Cynthia M Cipolla; Robert T Kennedy
Journal:  Anal Chem       Date:  2011-01-25       Impact factor: 6.986

7.  Miniaturizing sample spots for matrix-assisted laser desorption/ionization mass spectrometry.

Authors:  Tingting Tu; Michael L Gross
Journal:  Trends Analyt Chem       Date:  2009-08-01       Impact factor: 12.296

8.  MALDI MS Guided Liquid Microjunction Extraction for Capillary Electrophoresis-Electrospray Ionization MS Analysis of Single Pancreatic Islet Cells.

Authors:  Troy J Comi; Monika A Makurath; Marina C Philip; Stanislav S Rubakhin; Jonathan V Sweedler
Journal:  Anal Chem       Date:  2017-07-06       Impact factor: 6.986

  8 in total